VxRail: Node mangler fra fysisk side på grunn av deaktiverte CIM-agenter og Wbem
Summary: VxRail-noder kan forsvinne fra siden når VMK1-grensesnittet fjernes. Dette kan skyldes deaktiverte CIM-agenter (Common Information Model) og en inaktiv WBEM-tjeneste som blokkerer leverandører. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Noden mangler i den fysiske sidevisningen (VMK1 forsvinner automatisk).
Cause
CIM Agenter er deaktivert på noden.
Resolution
- Sørg for at
wbemer aktivert:esxcli system wbem get - Hvis
wbemer deaktivert, aktiver den med kommandoen:esxcli system wbem set enable true - Sjekk om alle
wbemLeverandører er lastet:localcli system wbem provider list[root@node1:] localcli system wbem provider list Name Enabled Loaded --------------------------------- sfcb_base true true vmw_base true true vmw_dcism true true vmw_hdr true true vmw_iodmProvider true true vmw_kmodule true true vmw_omc true true vmw_pci true true
- Hvis noen
wbemLeverandører er ikke lastet inn, aktiverCIMagenter (sfcbd-watchdogogwsman) ved hjelp av kommandoene nedenfor.[root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig sfcbd-watchdog sfcbd-watchdog off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig sfcbd-watchdog on [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog status sfcbd is not running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog start sfcbd-init: Getting Exclusive access, please wait... sfcbd-init: Exclusive access granted. sfcbd-init: Request to start sfcbd-watchdog, pid 2111224 sfcbd-config[2111234]: Configuration not changed, already enabled sfcbd-init: starting sfcbd sfcbd-init: Waiting for sfcb to start up. sfcbd-init: Program started normally. [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog status sfcbd is running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman wsman off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman status openwsmand is not running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman start openwsmand: Getting Exclusive access, please wait... openwsmand: Exclusive access granted. openwsmand: Starting openwsmand [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman status openwsmand is running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman wsman off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman on
- Kontroller at vmk1 er opprettet på noden nå.
- Sjekk den fysiske siden, og noden er i orden.