NetWorker: v9.0 VMware 작업을 CloudBoost 디바이스에 복제할 수 없음
Summary: VMware vProxy 세이브 세트를 CloudBoost로 복제할 수 없습니다. 잘못된 세이브 세트 ID, 작업 항목 없음, 오류: 지원되지 않는 노드가 있는 풀입니다. 원인: 노드 버전 9.1.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
VMware 백업(vProxy 백업) 세이브 세트를 CloudBoost 디바이스로 복제하는 작업이 실패합니다.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
실패의 mm/dd/yyyy hh:mm:ss meridiem> 시간에 < 데몬 로그를 검토하면 다음과 같은 메시지가 발견됩니다.
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
개선 요청. 알려진 문제: NW-I-404: NetWorker: CloudBoost 어플라이언스에 vProxy 세이브 세트의 클론을 생성하는 중입니다.
Resolution
제품 관리에서 이 개선 요청을 조사하고 있습니다. 요청이 아직 진행 중입니다. 고객 지원 센터에 문의하여 지원을 요청하고 문서 번호를 알려주십시오.
해결 방법: NetWorker 9.0.1 이상의 데이터 존에서 외장형 스토리지 노드를 구성합니다. 자세한 내용은 "NetWorker 9.1 CloudBoost 2.1 통합 가이드"의 "NetWorker 9.1: CloudBoost용 외장형 스토리지 노드를 사용하여 디바이스 구성"
해결 방법: NetWorker 9.0.1 이상의 데이터 존에서 외장형 스토리지 노드를 구성합니다. 자세한 내용은 "NetWorker 9.1 CloudBoost 2.1 통합 가이드"의 "NetWorker 9.1: CloudBoost용 외장형 스토리지 노드를 사용하여 디바이스 구성"
Affected Products
Cloud Backup & Protection, NetWorkerArticle Properties
Article Number: 000065416
Article Type: Solution
Last Modified: 04 Dec 2025
Version: 5