Dell Unity: Objekter viser ikke historiske ydeevnedata (kan rettes af brugeren)

Summary: Unity-objekter viser ikke historiske data.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

På Unity-systemet eller i CloudIQ kan kunderne ikke se historiske ydeevnedata for noget objekt.

Cause

Historiske metrics blev deaktiveret. 

Resolution

Deaktiver og genaktiver historikken ved at køre følgende UEMCLI-kommandoer:

uemcli /metrics/service set -historyEnabled no
uemcli /metrics/service set -historyEnabled yes

 

17:20:54 service@spa:~/user# uemcli /metrics/service set --help
Storage system port: 443
HTTPS connection

/metrics/service set -historyEnabled { yes | no }

Where:
   -historyEnabled
   Control historical metrics collection.

   [Possible usages]
      1. yes
         Enable historical metrics collection.

      2. no
         Disable historical metrics collection.

Affected Products