Dell Unity: Objekter viser ikke historiske ydeevnedata (kan rettes af brugeren)
Summary: Unity-objekter viser ikke historiske data.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
På Unity-systemet eller i CloudIQ kan kunderne ikke se historiske ydeevnedata for noget objekt.
Cause
Historiske metrics blev deaktiveret.
Resolution
Deaktiver og genaktiver historikken ved at køre følgende UEMCLI-kommandoer:uemcli /metrics/service set -historyEnabled nouemcli /metrics/service set -historyEnabled yes
17:20:54 service@spa:~/user# uemcli /metrics/service set --helpStorage system port: 443HTTPS connection
/metrics/service set -historyEnabled { yes | no }
Where: -historyEnabled Control historical metrics collection.
[Possible usages] 1. yes Enable historical metrics collection.
2. no Disable historical metrics collection.
Affected Products
Dell EMC Unity FamilyProducts
CloudIQ, Dell EMC Unity FamilyArticle Properties