Dell Unity: Falha na verificação de integridade pré-upgrade com o erro: Check_connectemc_sender_1

Summary: Falha na verificação de integridade pré-upgrade (PUHC) com o erro: ERROR_CODE=plataforma::check_connectemc_sender_1|Erro|NÃO É POSSÍVEL PROSSEGUIR COM O UPGRADE (corrigível pela Dell)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Falha na verificação de integridade pré-upgrade (PUHC) com o erro:
ERROR_CODE=platform::check_connectemc_sender_1|Error|
UPGRADE CANNOT PROCEED.
check_connectemc_sender_1
errors :0x1000300- Operation failed. Error code: 0x1000300 The requested object could not be found on the system. Recheck the command name. 0x6400bee - Failed to perform the operation because connect home has not been configured

Cause

Nota: A partir do Unity OE 5.3, ConnectHome Notificações de conectividade usando <serialNumber>@dell.com não são mais o padrão.


Ao configurar a conectividade do ConnectHome, inclua um endereço de e-mail do nome de domínio do sistema ou um endereço de e-mail aplicável aprovado na autenticação do servidor SMTP.

Para habilitar o SupportAssist na versão 5.3 e posterior, o ConnectEMC deve ter um endereço de e-mail "de".

Resolution

Há duas opções para resolver esse problema.

  1. Ignore o PUHC e realize o upgrade. Adicione o endereço de e-mail mais tarde.
  2. Adicione o endereço de e-mail do agora e, em seguida, execute o upgrade.


Opção 1: Ignore o PUHC e realize o upgrade

  1. Execute o comando abaixo:
svc_skip_puhc
  1. Execute o comando abaixo para ignorar o erro:
+58

50: flr::check_for_disk_transitions
51: flr::check_for_faulted_disks
52: flr::check_for_no_pulled_disks
53: flr::check_for_snaps_in_an_active_state
54: flr::check_movesession_exists
55: slic::check_for_slic_committed
56: platform::check_centralized_esrs_version
57: platform::check_unsupported_proxy
58: platform::check_connectemc_sender
  1. Quando check_connectemc_sender for ignorado. Inicie o upgrade no Unisphere.
  2. Adicione o endereço de e-mail de origem para ConnectEMC. (Veja abaixo)


Opção 2: Adicione o endereço de e-mail de origem e, em seguida, atualize

Há três opções para adicionar o endereço de e-mail de:

  1. Unisphere
  2. svc_connectemc Comandos
  3. Uemcli Comandos

Unisphere:

SMTP

svc_connectemc:

  1. Execute o comando abaixo para exibir ConnectEMC Status:
svc_connectemc -s

ConnectEMC: NOTRUNNING DISABLE
  1. Teste a capacidade do ConnectEMC para enviar uma mensagem para o suporte com o comando abaixo:
spa:/cores/service/user# svc_connectemc -t

ERROR [spa]: Email (ConnectEMC) not configured
  1. Execute o comando abaixo para exibir ConnectEMC Detalhes da configuração:
svc_connectemc -g

INFO [spa]: SMTP Host: smtp.server.com
INFO [spa]: SENDER EMAIL: DP-Unity01@dell.com
INFO [spa]: EMC Destination Email: emailalert@emc.com
  1. Execute o comando abaixo para definir o endereço de e-mail ConnectEMC Usa o para enviar alertas:
05:57:12 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc -m DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
ERROR [spa]: Email (ConnectEMC) not configured. Please enable connetEMC first.
  1. Execute o comando abaixo para ativar ConnectEMC:
05:58:30 root@CKM002XXXXX929 spa:/cores/service/user# svc_connectemc --enable 10.1XX.1XX.1X1 --sendermail DP-Unity01@dell.com

INFO [spa]: Verifying peer connectivity ...
INFO [spa]: Enabling ConnectEMC
INFO [spa]: Verifying peer connectivity ...
INFO [spa]: copying connectEMC config to peer
INFO [spa]: Persisting SMTP server configuration
INFO [spa]: Persisting sender email address configuration
INFO [spa]: ConnectEMC has been enabled successfully.
  1. Depois de ativar ConnectEMC, teste a conexão
    svc_connectemc -t
    INFO [spa]: Test Dialhome request 

Uemcli:

  1. Execute o comando abaixo para listar a configuração atual:
uemcli /sys/support/connecthome show -detail

1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = (none)@emc.com 
   E-mail to address  = emailalert@emc.com
Antes de ativar ConnectEMC, se você verificar o comando de teste, ele falhará com um erro: 
Operation failed. Error code: 0x1000300
The requested object could not be found on the system. Recheck the command name. (Error Code:0x1000300)
  1. Execute o comando abaixo para ativar o ConnectEMC
uemcli -d 10.0.0.1 -u local/joe -p Password /sys/support/connecthome set –enable yes –smtpServer 10.10.22.22 -emailFromAddr DP-Unity01@dell.com
Depois de ativar ConnectEMC, se você testá-lo, ele passa com sucesso:
09:05:02 root@CKM002XXXXX929 spb:/cores/service/user# uemcli -u admin -securepassword /sys/support/connecthome test
Password:
Storage system address: 127.0.0.1
Storage system port: 443
HTTPS connection

Remote certificate:
Issuer:   CN=DP-UNITY01
Subject:  CN=DP-UNITY01
Valid from: 2020:06:14:07:13:27
Valid to:  2023:06:14:07:13:27
Serial:   00a382cb17422be9fd
Id:     2957123456
Would you like to:
 [1] Accept the certificate for this session
 [2] Reject the certificate
Please input your selection (The default selection is [1]):
Operation completed successfully.
  1. Liste os detalhes atuais após a alteração de configuração:
uemcli /sys/support/connecthome show -detail

Please input your selection (The default selection is [1]):
1:  Enabled       = yes
   SMTP server     = 10.1XX.1XX.1X1
   E-mail from address = DP-Unity01@dell.com
   E-mail to address  = emailalert@emc.com

Additional Information

Affected Products