PowerProtect: OpenShift-säkerhetskopiering misslyckas med felet cproxy finns redan
Summary: Skyddsjobbet misslyckas på grund av felet "cproxy already exists".
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PowerProtect Data Manager-skyddsjobbet misslyckas med ett felmeddelande som liknar följande:
Error: Unable to backup PersistentVolumeClaims. PVC backup returned with an error: Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1'. Unable to create Pod 'XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy': pods "XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy" already exists Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1': Unable to create pod in safeguard limit of 10 minutes.
Det här problemet uppstår när följande villkor är uppfyllda:
- Det finns flera PVC-enheter som har samma första 40 tecken i sina namn.
- Parallell bearbetning av flera PVC:er är möjlig.
- PowerProtect Data Manager version 19.17.0-10 och tidigare används.
Cause
Detta är ett programvarufel.
Resolution
Problemet åtgärdas i PowerProtect Data Manager version 19.17.0–18.
Affected Products
PowerProtect Data ManagerArticle Properties
Article Number: 000228552
Article Type: Solution
Last Modified: 02 Sept 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.