Dell Networking VEP4600报告具有某些 SSD 日期代码的只读文件系统

Summary: Dell Networking VEP4600可能会报告带有某些 SSD 日期代码的只读文件系统。本文概述了可能出现的错误以及如何识别受影响的日期代码。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

VEP4600可能会遇到文件系统的读/写故障。日志显示类似于以下内容:

Apr  9 11:07:05 versa-flexvnf kernel: [5421388.862593] ata4.00: failed command: FLUSH CACHE EXT
Apr  9 11:07:05 versa-flexvnf kernel: [5421388.881723] ata4.00: status: { DRDY }
Apr  9 11:07:05 versa-flexvnf kernel: [5421388.867741] ata4.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 21
Apr  9 11:07:05 versa-flexvnf kernel: [5421388.855371] ata4.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen
Apr  9 11:07:05 versa-flexvnf kernel: [5421388.885569] ata4: hard resetting link
Apr  9 11:07:10 versa-flexvnf kernel: [5421394.207142] ata4: link is slow to respond, please be patient (ready=0)
Apr  9 11:07:15 versa-flexvnf kernel: [5421398.915488] ata4: hard resetting link
Apr  9 11:07:15 versa-flexvnf kernel: [5421398.910945] ata4: COMRESET failed (errno=-16)
Apr  9 11:07:20 versa-flexvnf kernel: [5421404.246725] ata4: link is slow to respond, please be patient (ready=0)
Apr  9 11:07:25 versa-flexvnf kernel: [5421408.934531] ata4: COMRESET failed (errno=-16)
Apr  9 11:07:25 versa-flexvnf kernel: [5421408.939075] ata4: hard resetting link
Apr  9 11:07:30 versa-flexvnf kernel: [5421414.290309] ata4: link is slow to respond, please be patient (ready=0)
Apr  9 11:08:00 versa-flexvnf kernel: [5421444.001617] ata4: limiting SATA link speed to 3.0 Gbps
Apr  9 11:08:00 versa-flexvnf kernel: [5421443.997078] ata4: COMRESET failed (errno=-16)
Apr  9 11:08:00 versa-flexvnf kernel: [5421444.001619] ata4: hard resetting link
Apr  9 11:08:05 versa-flexvnf kernel: [5421449.029612] ata4: EH complete
Apr  9 11:08:05 versa-flexvnf kernel: [5421449.025412] ata4: reset failed, giving up
Apr  9 11:08:05 versa-flexvnf kernel: [5421449.029600] ata4.00: disabled
Apr  9 11:08:05 versa-flexvnf kernel: [5421449.020870] ata4: COMRESET failed (errno=-16)

Cause

具有特定日期代码的VEP4600存在 SSD 变为只读的风险。受影响的具体日期代码是:

  1. 2308
  2. 2310
  3. 2312

查找日期代码

在 Versa OS 或 Dell DIAG-OS 中以根用户身份运行以下命令:”smartctl -i /dev/sda
响应应在响应的第五行包含一个序列号字段,其值类似于:YCA12310230490181

日期代码是序列号中 YCA1 之后开始的四位数值。在下面的示例中,2310 是日期代码。 

versa@versa-flexvnf:~$ sudo smartctl -i /dev/sda
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.4.0-151-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
 
=== START OF INFORMATION SECTION ===
Device Model:     256GB SATA Flash Drive
Serial Number:    YCA12310230490181
LU WWN Device Id: 6 71190a 55bd0d0d0
Firmware Version: SFDN004E
User Capacity:    256,060,514,304 bytes [256 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Apr 21 22:17:43 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

此示例设备受到影响。

Resolution

如果标识的代码与上述任何日期代码匹配,请联系支持部门以开始服务更换流程。 

Affected Products

DELL NETWORKING VEP4600 16-CORE, Dell Networking VEP4600 4-CORE, DELL NETWORKING VEP4600 8-CORE
Article Properties
Article Number: 000291005
Article Type: Solution
Last Modified: 09 Apr 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.