Connectrix MDS: M3: EOBC-hjerteslagsfejl i enhedens DEV_EOBC_MAC

Summary: M3-linjekortet kan nulstilles efter systemrapporter EOBC-hjerteslagsfejl:

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

M3-linjekortet kan nulstilles efter systemrapporter EOBC-hjerteslagsfejl:

 --- snip ---
 %MODULE-4-MOD_WARNING: Module X (Serial number: DUMMYNUMBER) reported warning X/1-X/0 due to EOBC heartbeat failure in device DEV_EOBC_MAC (device error 0xc0a0614f)
 %MODULE-4-MOD_WARNING: Module X (Serial number: DUMMYNUMBER) reported warning X/1-X/0 due to EOBC heartbeat failure in device DEV_EOBC_MAC (device error 0xc0a0614d)
 %MODULE-2-MOD_NOT_ALIVE: Module X not responding... resetting (Serial number: DUMMYNUMBER)
 --- snip ---

Cause

Kår:
Den særlige udløser kendes ikke, men problemet bør betinges som usædvanligt sjældent.

Resolution

Løsning:
Linjekort kommer online efter genindlæsning. Der foreslås ingen særlig løsning.

Additional Information

Nogle EOBC hjerteslag tab blev set på grund af hvilken LC blev genstartet og kom tilbage online. Årsagen til hjerteslag tab er ikke kendt, selv om dette er yderst sjældent.

Affected Products

Connectrix MDS-9250i, Connectrix MDS-9710
Article Properties
Article Number: 000185923
Article Type: Solution
Last Modified: 29 Aug 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.