Connectrix MDS: M3: EOBC-hjerteslagsfejl i enhedens DEV_EOBC_MAC
Summary: M3-linjekortet kan nulstilles efter systemrapporter EOBC-hjerteslagsfejl:
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
M3-linjekortet kan nulstilles efter systemrapporter EOBC-hjerteslagsfejl: --- snip ---
%MODULE-4-MOD_WARNING: Module X (Serial number: DUMMYNUMBER) reported warning X/1-X/0 due to EOBC heartbeat failure in device DEV_EOBC_MAC (device error 0xc0a0614f)
%MODULE-4-MOD_WARNING: Module X (Serial number: DUMMYNUMBER) reported warning X/1-X/0 due to EOBC heartbeat failure in device DEV_EOBC_MAC (device error 0xc0a0614d)
%MODULE-2-MOD_NOT_ALIVE: Module X not responding... resetting (Serial number: DUMMYNUMBER)
--- snip ---
Cause
Kår:
Den særlige udløser kendes ikke, men problemet bør betinges som usædvanligt sjældent.
Den særlige udløser kendes ikke, men problemet bør betinges som usædvanligt sjældent.
Resolution
Løsning:
Linjekort kommer online efter genindlæsning. Der foreslås ingen særlig løsning.
Linjekort kommer online efter genindlæsning. Der foreslås ingen særlig løsning.
Additional Information
Nogle EOBC hjerteslag tab blev set på grund af hvilken LC blev genstartet og kom tilbage online. Årsagen til hjerteslag tab er ikke kendt, selv om dette er yderst sjældent.