GDDR: Waarschuwingsmelding GDDUG24W resulteert in RC 8 in het configuratiedisplay
Summary: Waarschuwingsbericht GDDUG24W kan resulteren in een retourcode (RC) 8 op de configuratieschermen PRE-SCRIPT en PSOT-SCRIPT. Dit stopt scripts en vereist een overschrijving.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Tijdens GDDR-scripts (geografisch verspreid opnieuw opstarten na noodgevallen) kan het waarschuwingsbericht GDDUG24W resulteren in een Retourcode (RC) 8 op de schermen prescript- en postscript-configuratie.
GDDUG24W 2 external RDF groups indicate SRDF/A active GDDR639I GDDR Completed pre-script configuration display with RC 8
Cause
Dit is een berichtprobleem, er zou geen RC 8 in het waarschuwingsbericht moeten staan.
Resolution
Tijdelijke oplossing:
- Geen
Permanente oplossing:
- Voor GDDR 6.0 is de GD60004 Program Temporary Fix (PTF) beschikbaar om te downloaden van Dell Online Support.
- Voor GDDR 6.1 is het probleem opgelost in het basisproduct. Het kan worden gedownload van Dell Online Support.
Additional Information
Beschrijving tijdelijke oplossing programma:
++PTF(GD60004) REWORK(2022315) . ++VER(Z038) FMID(GDDR600) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * * PROBLEM FIXED: GDDR-3459 * USERS AFFECTED: GDDR users * PROBLEM DESCRIPTION: Warning message GDDUG24W results in * RC 8 on pre-script and post-script * configuration displays * * DESCRIPTION DETAIL: * * During GDDR scripts, warning message GDDUG24W could result * in an RC 8 on the pre-script and post-script configuration * displays, for example: * * GDDUG24W 2 external RDF groups indicate SRDF/A active * GDDR639I GDDR Completed pre-script configuration display * with rc 8 * * This is simply a messaging issue, as a non-zero RC on the * configuration displays does not affect the outcome of the * script. * * PROBLEM RESOLUTION: * * Warning message GDDUG24W will now result in an RC 4 on the * configuration displays, as expected. * MODULES: GDDRMCMD * * ------------------------------------------------------------
Affected Products
Geographically Dispersed Disaster Restart (GDDR)Article Properties
Article Number: 000203774
Article Type: Solution
Last Modified: 07 Aug 2025
Version: 3