PowerFlex 3.X:在 FG SP 中執行 vtree 遷移時,SDS 程序間歇性發生錯誤

Summary: 執行精細度 (FG) vtree 遷移時,SDS 程序可能會間歇性錯誤。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

SDS 發生錯誤,以下堆疊追蹤如下所示,在功能spefStorageRegion_FillCompressedMessage

2023/02/13 08:23:46.078303 Panic in file /data/build/workspace/ScaleIO-Common-Job/src/tgt/storage/spef_impl/spef_storage_region.c, line 4943, function spefStorageRegion_FillCompressedMessage, PID 17933.Panic Expression !(((void *)0) == pBuff) PANIC_ID_tgt_1594023094280.
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(mosDbg_PanicPrepare+0x13a) [0x93ab8a]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(spefStorageRegion_FillCompressedMessage+0x2a5) [0x80f625]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(raidComb_WriteCombRemote+0x168c) [0x75232c]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107() [0x753098]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107() [0x5dd1f6]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(raidComb_Write+0xf0) [0x5de710]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(iohComb_WritePrimary+0x405) [0x5f5705]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(ioh_Write+0x521) [0x5f6411]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(ioh_NewRequest+0x3085) [0x5fc4a5]
/opt/emc/scaleio/sds/bin/sds-3.6.300.107(contNet_RecvIORequest+0x2c4) [0x601534]

Cause

遷移壓縮卷時,目標 SDS 可能會收到已完全修剪或使用零寫入的遷移數據。如果發生這種情況,SDS 可能無法正確處理數據,這可能會導致 SDS 重新啟動或崩潰。這是磁碟區遷移期間可能會出現的問題。

Resolution

將 PowerFlex 升級至 v3.6.1 或 v4.x 及更新版本。