PowerFlex: How to reset oscillating_failure_counters from the Primary MDM
Summary: This Article explains how to reset the oscillating_failure_counters from the primary MDM Oscillating_failure_counters are used to trace the all-time number of networks flapping between nodes, and to understand if this is an ongoing problem or a historical problem, counters must be reset. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Oscillating_failure_counters are used to trace the all-time number of networks flapping between nodes, and to understand if this is an ongoing problem or a historical problem; counters must be reset.
Resetting oscillating_failure_counters on the Primary MDM
- Log in to the Primary MDM with SSH
- Log in to the cluster with
scli --login --username admin - Perform the following command
scli --reset_oscillating_failure_counters --all_counters --all_sdc - Will prompt you to enter 'Y" to approve this certificate and add it to the truststore.
- When finished, update inventory on Gateway
Additional Information
Related Article: PowerFlex: Oscillating Failure Counter Parameter SIO01.03.0000001 and SIO01.03.0000002