Avamar:Data Domain 的後端容量報告無法執行:「功能未啟用」

Summary: Avamar 後端容量報告未針對 Data Domain 執行,報告「功能未啟用」。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Data Domain (DD) 的後端容量報告不會執行,並報告「功能未啟用」(如下所示):

kA2j0000000RKTMCA4_3_0

 

Cause

Data Domain 的後端容量報告需要 compression physical-capacity-measurement Data Domain 作業系統 (DDOS) 5.7.x 和更高版本上的功能,要啟用。

Resolution

1.請確定 Data Domain 執行的是 DDOS 5.7.x 或更新版本。

2.確認 Data Domain 上已啟用實體容量測量功能:

compression physical-capacity-measurement status
 

若已啟用:

physical-capacity-measurement is enabled.
Initialization was not requested.
 

如果已停用:

physical-capacity-measurement is disabled.
 

3.如果已停用,請使用下列命令啟用:

compression physical-capacity-measurement enable
physical-capacity-measurement enabled.