VPLEX: Distribueret enhedshierarki mangler omfang

Summary: I denne artikel omtales det problem, hvor hierarkiet for distribuerede enheder mangler et omfang, og hvordan det manglende omfang afhjælpes.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



Når du får vist komponenthierarkiet for en distribueret enhed, mangler et enhedsben et omfang.

VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
  consistency-group: CG-CS-Test (synchronous)
    virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
      distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
        distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
          extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
            storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
              logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
                storage-array: EMC-CLARiiON-APM00xxxxxxxxx
        distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1)

                                                                                                                                            <-- The missing extent is expected here.
          storage-volume: CLARiiON1234_LUN_00030 (1G)
            logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
              storage-array: EMC-CLARiiON-APM00xxxxxxxxx



Når de distribuerede enhedskomponenter er angivet, vises en som et omfang med geometrien "udsnit".

VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/

/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name                                Cluster    Child  Fully   Operational  Health  Block   Block  Capacity  Geometry  Total
----------------------------------  ---------  Slot   Logged  Status       State   Count   Size   --------  --------  FreeSpace
----------------------------------  ---------  -----  ------  -----------  ------  ------  -----  --------  --------  ---------
device_C2_CLARiiON1234_LUN_00015_1  cluster-2  1      true    ok           ok      262144  4K     1G        raid-0    -
extent_CLARiiON1234_LUN_00030_1     cluster-1  0      true    ok           ok      262144  4K     1G        slice     - <-- N
ote the "Geometry" for this extent is listed as 'slice'.

 

Cause

Dette problem kan i sjældne tilfælde opstå som følge af en omfattende migrering af diskenheden. Når migreringen er fuldført, mangler der en R0-enhed (RAID 0) ud over omfanget i komponenthierarkiet.

Resolution

Den manglende R0-enhed i komponenthierarkiet er et kosmetisk problem. Det vil ikke have nogen mærkbar indvirkning på VPLEX-handlingerne, hvis enheden forbliver i denne tilstand. Hvis du imidlertid ønsker en løsning på dette kosmetiske problem, skal du åbne en serviceanmodning hos VPLEX-support og nævne denne artikel. 

Løsningen på dette skærmproblem er at bruge interne firmwarekommandoer til at indsætte en ny R0-enhed oven på omfanget. Denne proces vil ikke forårsage nogen påvirkning, men bør kun gennemføres af teknisk support.

Permanent rettelse:
Da dette er et kosmetisk problem, er der ingen permanent løsning på nuværende tidspunkt.

Additional Information

Affected Products

VPLEX Series

Products

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000167451
Article Type: Solution
Last Modified: 05 Sept 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.