VPLEX:分布式设备层次结构是缺失的扩展区

Summary: 本文讨论分布式设备层次结构缺少数据区的问题,以及如何解决数据区缺失的问题。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



查看分布式设备的组件层次结构时,设备分支缺少扩展区。

VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
  consistency-group: CG-CS-Test (synchronous)
    virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
      distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
        distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
          extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
            storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
              logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
                storage-array: EMC-CLARiiON-APM00xxxxxxxxx
        distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1)

                                                                                                                                            <-- The missing extent is expected here.
          storage-volume: CLARiiON1234_LUN_00030 (1G)
            logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
              storage-array: EMC-CLARiiON-APM00xxxxxxxxx



列出分布式设备组件时,其中一个组件将显示为几何结构为“切片”的扩展区。

VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/

/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name                                Cluster    Child  Fully   Operational  Health  Block   Block  Capacity  Geometry  Total
----------------------------------  ---------  Slot   Logged  Status       State   Count   Size   --------  --------  FreeSpace
----------------------------------  ---------  -----  ------  -----------  ------  ------  -----  --------  --------  ---------
device_C2_CLARiiON1234_LUN_00015_1  cluster-2  1      true    ok           ok      262144  4K     1G        raid-0    -
extent_CLARiiON1234_LUN_00030_1     cluster-1  0      true    ok           ok      262144  4K     1G        slice     - <-- N
ote the "Geometry" for this extent is listed as 'slice'.

 

Cause

在极少数情况下,卷上的扩展区迁移可能会导致此问题。迁移完成后,组件层次结构中的扩展区顶部缺少 R0 (RAID 0) 设备。

Resolution

组件层次结构中缺少 R0 设备是表面问题。将设备保留在此状态不会对 VPLEX作产生任何明显影响。但是,如果需要解决此表面问题,请向 VPLEX 支持部门提出服务请求并提及本文。

此显示问题的解决方法是使用内部固件命令在数据区顶部插入新的 R0 设备。此过程不会造成任何影响,但只能由技术支持人员完成。

永久修复:
由于这是一个表面问题,目前没有永久的修复方法。

Additional Information

Affected Products

VPLEX Series

Products

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000167451
Article Type: Solution
Last Modified: 05 Sept 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.