MDM 未同步時,PowerFlex 切換失敗
Summary: 網路連線問題會導致次要 MDM 狀態變成未同步。
Symptoms
劇本
一致的 MDM 中斷連線,以及主要和次要 MDM 之間的連線問題,會導致次要 MDM 狀態變成未同步。
症狀
主要和次要 MDM 之間缺乏一致的連線會顯示下列症狀:
scli --query_cluster 的輸出顯示次要 MDM/s 已中斷連線。
scli --query_cluster 的輸出顯示次要 MDM/s 未同步。
Cmatrix 顯示重建停滯。
SDC<>SDS 連線能力問題 (SDS 位於有問題的 MDM 上)。
query_all output:
(info) Notice the Secondary MDMs' status.
Status: Not synchronized
Cluster:
Name: parsio, ID: 06002ca3767a6153, Mode: 5_node, State: Degraded, Active: 5/5, Replicas: 1/3
Virtual IPs: 192.168.20.100
Master MDM:
Name: parsiomanager2, ID: 0x148190e6333dbc12
IPs: 192.168.20.2, Management IPs: 10.8.8.56, Port: 9011, Virtual IP interfaces: eth1
Version: 2.6.10000
Actor ID: 0x1d0ac48b18c6f742, Voter ID: 0x2bb7b8b1353f6a82
Certificate Info:
Subject: /GN=MDM/CN=ScaleIO-10-8-8-56/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Issuer: /GN=MDM/CN=ScaleIO-10-8-8-56/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Valid From: Apr 2 11:25:03 2019 GMT
Valid To: Mar 31 12:25:03 2029 GMT
Thumbprint: 60:C0:50:38:FC:3D:49:D5:00:8F:9F:CE:4F:27:D2:23:A1:E3:07:AF
Slave MDMs:
Name: parsiomanager1, ID: 0x51ddc23b3cddea90
IPs: 192.168.20.1, Management IPs: 10.8.8.54, Port: 9011, Virtual IP interfaces: eth1
Status: Not synchronized, Version: 2.6.10000
Actor ID: 0x641bc8002b885d00, Voter ID: 0x06f3ab9245ee83d0, Replication State: Synchronization in-progress
Certificate Info:
Subject: /GN=MDM/CN=ScaleIO-10-8-8-54/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Issuer: /GN=MDM/CN=ScaleIO-10-8-8-54/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Valid From: Apr 2 11:33:08 2019 GMT
Valid To: Mar 31 12:33:08 2029 GMT
Thumbprint: A3:49:37:C3:66:2F:53:05:96:2D:74:10:1F:D2:DF:A4:E7:F5:85:7B
Name: parsiomanager3, ID: 0x3bf30e1a42079e61
IPs: 192.168.20.4, Management IPs: 10.8.8.59, Port: 9011, Virtual IP interfaces: eth1
Status: Not synchronized, Version: 2.6.10000
Actor ID: 0x667027d528ddfcd1, Voter ID: 0x493913d41133d6b1, Replication State: Synchronization in-progress
Certificate Info:
Subject: /GN=MDM/CN=ScaleIO-10-8-8-59/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Issuer: /GN=MDM/CN=ScaleIO-10-8-8-59/L=Hopkinton/ST=Massachusetts/C=US/O=EMC/OU=ASD
Valid From: Apr 2 10:17:11 2019 GMT
Valid To: Mar 31 11:17:11 2029 GMT
Thumbprint: E9:10:DD:56:E9:2D:C8:6F:ED:D8:57:75:FF:DF:BB:15:41:FA:C1:32
Tie-Breakers:
Name: parsiotb1, ID: 0x3c5587221ac0cfe4
IPs: 192.168.20.3, Port: 9011
Status: Normal, Version: 2.6.10000
Voter ID: 0x683fd39d2af27284
Name: parsiotb2, ID: 0x20c2b3f30969f533
IPs: 192.168.20.5, Port: 9011
Status: Normal, Version: 2.6.10000
MDM 事件:
(資訊)請注意 MDM 和 SDC 與 SDS 的多次中斷連線,範例如下。
MDM,ID 51ddc23b3cddea90,連線中斷。
MDM,ID 3bf30e1a42079e61,沒有回應。
SDC ID:9503ac9800000003 與 SDS parsioesx02.ansys.com-ESX 的 IP 192.168.20.2 中斷連線;ID:10d84abe00000002
4856 2020-12-01 12:19:38.735 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4857 2020-12-01 12:19:38.204 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4858 2020-12-01 12:19:43.397 MDM_CLUSTER_NOT_RESPOND WARNING The MDM, ID 3bf30e1a42079e61, is not responding 4859 2020-12-01 12:19:44.824 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 3bf30e1a42079e61, lost connection 4860 2020-12-01 12:19:44.203 MDM_CLUSTER_CONNECTED INFO The MDM, ID 3bf30e1a42079e61, connected 4861 2020-12-01 12:19:44.569 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4862 2020-12-01 12:19:44.701 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4863 2020-12-01 12:19:45.276 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4864 2020-12-01 12:19:45.397 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4865 2020-12-01 12:19:48.480 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 3bf30e1a42079e61, lost connection 4866 2020-12-01 12:19:48.601 MDM_CLUSTER_CONNECTED INFO The MDM, ID 3bf30e1a42079e61, connected 4867 2020-12-01 12:19:49.431 SDC_DISCONNECTED_FROM_SDS_IP WARNING SDC ID: 9503ac9800000003 disconnected from IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4868 2020-12-01 12:19:50.377 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4869 2020-12-01 12:19:50.403 SDC_CONNECTED_TO_SDS_IP INFO SDC ID: 9503ac9800000003 is now connected to IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4870 2020-12-01 12:19:50.498 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4871 2020-12-01 12:19:51.183 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 3bf30e1a42079e61, lost connection 4872 2020-12-01 12:19:51.304 MDM_CLUSTER_CONNECTED INFO The MDM, ID 3bf30e1a42079e61, connected 4873 2020-12-01 12:19:53.669 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4874 2020-12-01 12:19:53.800 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4875 2020-12-01 12:19:54.833 SDC_DISCONNECTED_FROM_SDS_IP WARNING SDC ID: 9503ac9800000003 disconnected from IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4876 2020-12-01 12:19:56.858 SDC_CONNECTED_TO_SDS_IP INFO SDC ID: 9503ac9800000003 is now connected to IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4877 2020-12-01 12:19:56.867 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 3bf30e1a42079e61, lost connection 4878 2020-12-01 12:19:56.197 MDM_CLUSTER_CONNECTED INFO The MDM, ID 3bf30e1a42079e61, connected 4879 2020-12-01 12:19:56.873 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4880 2020-12-01 12:19:57.426 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected 4881 2020-12-01 12:19:58.284 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 3bf30e1a42079e61, lost connection 4882 2020-12-01 12:19:58.405 MDM_CLUSTER_CONNECTED INFO The MDM, ID 3bf30e1a42079e61, connected 4883 2020-12-01 12:19:59.995 SDC_DISCONNECTED_FROM_SDS_IP WARNING SDC ID: 9503ac9800000003 disconnected from IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4884 2020-12-01 12:20:00.997 SDC_CONNECTED_TO_SDS_IP INFO SDC ID: 9503ac9800000003 is now connected to IP 192.168.20.2 of SDS parsioesx02.ansys.com-ESX; ID: 10d84abe00000002 4885 2020-12-01 12:20:01.372 MDM_CLUSTER_LOST_CONNECTION WARNING The MDM, ID 51ddc23b3cddea90, lost connection 4886 2020-12-01 12:20:01.503 MDM_CLUSTER_CONNECTED INFO The MDM, ID 51ddc23b3cddea90, connected
MDM trc.x:
(資訊)請注意,多個梳子進入降級狀態並開始重新建置,範例如下。
多頭:f7c90002 行:1022 降級->降級 (INITIATE_MIGRATE)
01/12 12:21:31.587572 0x7f24a0ad6eb0:multiHeadRow_MoveState_Inner:02966: [multiHead_HandleMigrate:892]: MultiHead: f7c90002 Row: 1022 DEGRADED->DEGRADED (INITIATE_MIGRATE) 01/12 12:21:31.587578 0x7f24a0ad6eb0:multiHeadRow_MoveState_Inner:02966: [multiHead_HandleMigrate:892]: MultiHead: f7c90002 Row: 380 DEGRADED->DEGRADED (INITIATE_MIGRATE) ... 01/12 12:21:31.590164 0x7f24a064deb0:mdmTgtMsg_SendAsyncAddSingleCombEX:04000: TgtId: 10d871cb00000000 CombId: 7be4000081e9 CombState: SECONDARY raid: [tgtId: 10d84abe00000002, state: 0x1, type: SECONDARY] primaryTgtGenNum: 121 mdmTgtConnectionGenNum: 7311 tgtCombCmdGenNum: 1 01/12 12:21:31.590407 0x7f24a0ae8eb0:mdmTgtMsg_SendAsyncStartMigrate:04605: TgtId: 10d84abe00000002 CombId: 7be4000081e9 MigrateTo:10d871cb00000000 primaryTgtGenNum: 121 tgtCombCmdGenNum: 461 mdmTgtConnectionGenNum: 7346 migrateNum: 246 isFwdRebuild: 1 01/12 12:21:31.590552 0x7f24a0ae8eb0:multiHeadRow_MoveState_Inner:02966: [multiHead_HandleMigrate:892]: MultiHead: f7c80001 Row: 489 DEGRADED->DEGRADED (INITIATE_MIGRATE) ... 01/12 12:21:31.592950 0x7f24a0833eb0:mdmTgtMsg_SendAsyncAddSingleCombEX:04000: TgtId: 10d8bfeb00000004 CombId: 7be38000034a CombState: SECONDARY raid: [tgtId: 10d84abe00000002, state: 0x1, type: SECONDARY] primaryTgtGenNum: 128 mdmTgtConnectionGenNum: 4958 tgtCombCmdGenNum: 1 01/12 12:21:31.592958 0x7f24a0833eb0:mdmTgtMsg_SendAsyncAbortMigrate:04674: TgtId: 10d84abe00000002 CombId: 7be3800001b8 primaryTgtGenNum: 70 tgtCombCmdGenNum: 592 mdmTgtConnectionGenNum: 7346 01/12 12:21:31.592971 0x7f24a0833eb0:mdmTgtMsg_SendAsyncAbortMigrate:04674: TgtId: 10d84abe00000002 CombId: 7be3800000eb primaryTgtGenNum: 152 tgtCombCmdGenNum: 623 mdmTgtConnectionGenNum: 7346 01/12 12:21:31.593121 0x7f24a0ae8eb0:mdmTgtMsg_SendAsyncFreeComb:04408: TgtId: 10d871cb00000000 CombId: 7be3800001b8 mdmTgtConnectionGenNum: 7311 01/12 12:21:31.593138 0x7f24a0ae8eb0:mdmTgtMsg_SendAsyncFreeComb:04408: TgtId: 10d898de00000001 CombId: 7be3800000eb mdmTgtConnectionGenNum: 7321
Cmatrix 輸出:
(資訊)請注意,重新建置已停止,因此看起來似乎停滯在 UI 中,例如如下所示。
原則 = REBUILD_STOPPED、問題 = 多重、冷靜關閉 = FALSE、略過 = FALSE
--------------------------------------------------------------------------
cmatrix status dump (FdID=8ba78f9f00000000, 01/12 11:00:54.998786)
policy=REBUILD_STOPPED, issue=MULTIPLE, coolingOff=FALSE, bypass=FALSE
nMaxRows=032, nActiveRows=005, nKnownTgts=005
matrixGen=495, nCycles=2377, duration [ms]: average<1, max=0
matrix memory foot-print is 17344 [bytes]
row/ column ownership:
i=000 :: tgtId=10d871cb00000000 (fsId=10d871cb00000000)
i=001 :: tgtId=10d898de00000001 (fsId=10d898de00000001)
i=002 :: tgtId=10d84abe00000002 (fsId=10d84abe00000002)
i=003 :: tgtId=10d898ee00000003 (fsId=10d898ee00000003)
i=004 :: tgtId=10d8bfeb00000004 (fsId=10d8bfeb00000004)
cells:
I+D++
+I+++
+DI++
+++I+
++++I
影響
MDM 叢集未同步,在此狀態下無法進行 MDM 切換。
反覆失去連線會導致檢修性中斷。
重新建置卡住,系統處於 DU 的潛在單一故障點。
SDC 上可能會出現 IO 錯誤。
Cause
當主 MDM 必須更改資料塊的狀態時,它必須將這些狀態更改寫入 MDM 儲存庫檔,然後將這些更改同步到從屬 MDM。當這些寫入操作完成後,MDM 會通知 SDS 變更已完成,然後他們可以繼續服務,僅從主要複本將 IO 寫入 SDC (直到重建完成)。
一旦主要 MDM 無法更新次要 MDM,就會導致 MDM 無法足夠快速地回應 SDS 要求,並可能導致 SDC 發生 IO 錯誤。
由於集群成員之間缺乏同步而無法進行 MDM 切換,並且問題似乎出在主 MDM 上,因此必須在系統中添加另一個 MDM,在不存在連接問題的其他位置,並將其替換為其中一個輔助 MDM,然後切換到它, 以這種方式將有問題的主要 MDM 踢出群集。
Resolution
因應措施
在 SVM 環境中,若 GW VM 不在 ESXi 伺服器的本機磁碟機上,則可將其用於安裝作業和進行切換的新 MDM,並可由 vMotion 處理至沒有此問題的其他 ESXi,或在任何 VM 上安裝 MDM 以取得此因應措施。
在非 SVM 環境中,虛擬機或非 MDM 節點可用於安裝操作,新 MDM 可用於切換。
受影響的版本
不適用,網路問題
已修正問題的版本
N/A