Connectrix B-Series: 문제: 프로세스 0.weblinker.fcg에 대한 SCN 대기열 오버플로
Summary: 프로세스 0.weblinker.fcg 오류에 대한 SCN 대기열 오버플로를 발견했습니다.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
2024/06/18-04:08:49 (GMT), [SCN-1001], 6077, SLOT 2 | FFDC | CHASSIS, CRITICAL, ED_DCX7_8B, SCN queue overflow for process 0.weblinker.fcg 2024/06/18-04:08:49 (GMT), [SCN-1001], 6078, SLOT 2 | FFDC | CHASSIS, CRITICAL, ED_DCX7_8B, SCN queue overflow for process 0.weblinker.fcg
RAS 로그:
2024/06/18-04:03:44:626847 (GMT), [C5-5668], 0, SLOT 2 | CHASSIS | PORT 3/40, ERROR, ED_DCX7_8B, S3,P40(73): Port Fault: Hard 0(2) fault1=100 fault2=5 (0x64 0x0 0x0), OID:0x43328809, SPOID:0x43368128, c 2024/05/24-10:23:16 (GMT), [MS-1009], 742, SLOT 2 | FID 128 | PORT 4/17, ERROR, BCC_CORE_SAN_05, RLIR event Slot/Port 4/17 (0x0C7100) Device Port Tag is 0x0333,Loss of Signal or Synchronization.
supportsave 번들에서 추출된 diag.log 파일에 검사가 필요한 심각한 오류가 포함되어 있습니다. 다음은 dial.log에서 발췌한 내용입니다.
2024/06/15-00:02:42:595136 (GMT), [C5-5668], 0, SLOT 2 | CHASSIS | PORT 11/40, ERROR, ED_DCX7_8B, S11,P616(73): Port Fault: Hard 0(2) fault1=100 fault2=5 (0x64 0x0 0x0), OID:0x43b28809, SPOID:0x43b68128, c5
Cause
일부 디바이스에서 플래핑이 발생하면 weblinker가 모든 상태 변경으로 인한 대기열을 따라갈 수 없는 중단이 발생했을 수 있습니다.
Weblinker는 오작동하는 장치로 인해 문제에 직면합니다. 플래핑 ISL 또는 포트 장애에 관계없이 이러한 문제는 중단 이벤트에 대한 RAS 로그를 검토해야 합니다.
Weblinker는 오작동하는 장치로 인해 문제에 직면합니다. 플래핑 ISL 또는 포트 장애에 관계없이 이러한 문제는 중단 이벤트에 대한 RAS 로그를 검토해야 합니다.
Resolution
오작동하는 포트(플래핑 ISL 또는 포트 장애)를 조사해야 합니다.