Connectrix MDS 9148S 重新启动,无法处理地址0x0000003c处数据的内核分页请求

Summary: Connectrix MDS 9148S 已重新启动,无法处理地址为 0x0000003c 的数据的内核分页请求。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

由于内核死机,在 8.4(2d) 上运行的交换机 MDS 9148S 重新启动。
`show system reset-reason module 1`
----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) ---
1) At 952261 usecs after Mon Apr 24 05:28:51 2023
    Reason: Kernel Panic
    Service:
    Version: 8.4(2d)
No cores saved.
命令 show system internal kernel nvram-messages previous 输出显示以下内容:
Unable to handle kernel paging request for data at address 0x0000003c
Faulting instruction address: 0xc02358cc
KGDB: Waiting for remote debugger
Start stack dumping
Moving to kernel stack
Done stack dumping
Start register dumping
Done register dumping
Done all dumping 4586 8196
**** KERNEL PANIC OCCURED*******
Writing reset reason. Irqs 1
Writing stack trace
Writing kernel traces
Starting dump of trace eventsTrace events filled bufferFinished dump of trace eventsin.dcos-telnetd:18248 /debugfs/tracing/per_cpu/cpu0/trace_pipe_raw read done, size 3010560
in.dcos-telnetd:18248 /debugfs/tracing/per_cpu/cpu1/trace_pipe_raw read done, size 3084288
Buffer read= 2089152
Resetting board
命令 show accounting log 指示同时配置终端宽度和终端长度,然后会话关闭。
Mon Apr 24 05:20:52 2023:type=update:id=10.x.x.x@pts/1:user=scripten:cmd=terminal width 511 (SUCCESS)
Mon Apr 24 05:20:52 2023:type=update:id=10.x.x.x@pts/1:user=scripten:cmd=terminal length 0 (SUCCESS)
Mon Apr 24 05:20:53 2023:type=update:id=10.x.x.x@pts/2:user=SRVC_A006AC_0004_PRD:cmd=terminal session-timeout 60 (SUCCESS)
Mon Apr 24 05:20:53 2023:type=update:id=10.x.x.x@pts/2:user=SRVC_A006AC_0004_PRD:cmd=terminal length 0 (SUCCESS)
Mon Apr 24 05:21:05 2023:type=stop:id=10.x.x.x@pts/1:user=scripten:cmd=shell terminated because the ssh session closed
Mon Apr 24 05:25:49 2023:type=stop:id=10.x.x.x@pts/2:user=SRVC_A006AC_0004_PRD:cmd=shell terminated because the ssh session closed

Cause

上述调查结果表明,该问题是由 Cisco 问题 CSCwe09965 引起的,https://bst.cisco.com/bugsearch/bug/CSCwe09965本超链接将引导您访问非 Dell Technologies 运营的网站。 (需要登录 Cisco 才能查看文章)

症状:
MDS 9148S 交换机由于内核死机而重新加载。显示的原因 show system reset-reason 命令为:原因:内核崩溃
进一步的问题说明:
此问题的触发因素未知。内核崩溃会导致系统重新加载,并在重新加载期间中断流量。
条件:
此问题适用于任何 MDS 平台。

Resolution

解决方法:
避免在关闭会话的同时设置终端宽度或长度。

不要同时配置终端宽度和终端长度,然后关闭会话,或避免使用任何不断设置终端宽度和长度的脚本。

分辨率:
此问题已在 8.4(2f)、9.3.1 和 9.4.x 版本中得到解决。

Affected Products

Connectrix MDS-9148S
Article Properties
Article Number: 000212786
Article Type: Solution
Last Modified: 28 May 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.