Connectrix - B 系列 - 许可证系统完整性检查失败,许可证作被阻止

Summary: 由于超出风扇温度,交换机状态更改为“marginal”,即使风扇和电源设备处于运行状态也是如此。 此问题是“license system integrity check failed, license operations are blocked”警报或错误所致。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • 即使风扇和电源设备正常运行且 RPM 良好,风扇仍报告高温。
  • 在错误转储中观察到以下消息或警报:

    [HIL-1506], 7647, FFDC | CHASSIS, CRITICAL, DS_6620B, High temperature (304 C) exceeds system temperature limit. System will shut down within 2 minutes.
    
    [LIC-1009], 15494, CHASSIS, CRITICAL, DS_6620B,  License system integrity check failed, license operations are blocked.

Cause

错误表示许可证公钥哈希检查失败。
这由 Broadcom 执行。 

Resolution

解决办法:

-- 重新启动交换机并检查状态。 

修复:

-- 更换交换机。

说明:上述步骤应在维护窗口期间执行,因为它会中断 FC 流量。 

Affected Products

Brocade G620
Article Properties
Article Number: 000308413
Article Type: Solution
Last Modified: 17 Apr 2025
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.