PowerScale: SyncIQ replikerer ikke adgangstiden (atime) til målklyngen

Summary: Når du replikerer data ved hjælp af SyncIQ, hvis en filadgangstid (atime) er ændret på produktionsklyngen. Adgangstid (klokkeslæt) replikeres ikke til destinationsklyngen, når SyncIQ fuldfører replikeringen. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Example:
 

Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045    FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1001450/(1001450))  Gid: (1000069/(1000069))
Device: 136,1757282482   Inode: 4314169351    Links: 3
Access: Wed Jun 14 13:56:49 2023    <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023


Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045      FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1000759/(1000759))  Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268   Inode: 51447964289    Links: 3
Access: Sun Jun 11 09:08:35 2023   <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023

Cause

SyncIQ baserer al sin ændringsoverførsel på attributter, der er synlige i et snapshot. SyncIQ kan kun overføre en gang fra kilde til mål. Når en kildefil har haft en anden ændring, der udløser en COW, for eksempel en tilladelsesændring.

Resolution

Dette er tilsigtet, at der er indsendt en anmodning om funktionsforbedring for fremtidig kode.
Article Properties
Article Number: 000215411
Article Type: Solution
Last Modified: 02 Jan 2026
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.