PowerScale: SyncIQ replikerar inte åtkomsttid (atime) till målklustret

Summary: När du replikerar data med SyncIQ, om en filåtkomsttid (atime) har ändrats i produktionsklustret. Åtkomsttiden (atime) replikeras inte till målklustret när SyncIQ slutför replikeringen. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Example:
 

Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045    FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1001450/(1001450))  Gid: (1000069/(1000069))
Device: 136,1757282482   Inode: 4314169351    Links: 3
Access: Wed Jun 14 13:56:49 2023    <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023


Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045      FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1000759/(1000759))  Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268   Inode: 51447964289    Links: 3
Access: Sun Jun 11 09:08:35 2023   <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023

Cause

SyncIQ baserar all ändringsöverföring på attribut som visas i en ögonblicksbild. SyncIQ kan endast överföra en tid från källa till mål. När en källfil har haft någon annan ändring som utlöser en COW, till exempel en behörighetsändring.

Resolution

Detta är avsiktligt, en funktionsförbättringsbegäran har skickats för framtida kod.