PowerScale: SyncIQ replikerar inte åtkomsttid (atime) till målklustret
Summary: När du replikerar data med SyncIQ, om en filåtkomsttid (atime) har ändrats i produktionsklustret. Åtkomsttiden (atime) replikeras inte till målklustret när SyncIQ slutför replikeringen. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Example:
Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1001450/(1001450)) Gid: (1000069/(1000069))
Device: 136,1757282482 Inode: 4314169351 Links: 3
Access: Wed Jun 14 13:56:49 2023 <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023
Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1000759/(1000759)) Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268 Inode: 51447964289 Links: 3
Access: Sun Jun 11 09:08:35 2023 <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023Cause
SyncIQ baserar all ändringsöverföring på attribut som visas i en ögonblicksbild. SyncIQ kan endast överföra en tid från källa till mål. När en källfil har haft någon annan ändring som utlöser en COW, till exempel en behörighetsändring.
Resolution
Detta är avsiktligt, en funktionsförbättringsbegäran har skickats för framtida kod.