PowerScale: Linux CEE Debugging and Log Gather
Summary: How to enable Common Event Enabler (CEE) Debugging on a Linux CEE box.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
While running a Linux CEE, debug mode can be enabled in order to gather more advanced data for troubleshooting, follow the steps below:
Copy the configuration file to allow simple restoration:
#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.bak Edit the /opt/CEEPack/emc_cee_config.xml configuration file to set both debug and Verbose to 63.
#vi /opt/CEEPack/emc_cee_config.xml Under Configuration, find "Debug" and "Verbose" and change value to 63:
<Configuration>
<CacheSize>100</CacheSize>
<Debug>63</Debug>
<HeartBeatIntervalSecs>10</HeartBeatIntervalSecs>
<InstrIntervalSecs>60</InstrIntervalSecs>
<NumberOfThreads>20</NumberOfThreads>
<Verbose>63</Verbose>
<HttpPort>12228</HttpPort>
<DirDBPath></DirDBPath>
<WatchDog>
<RestartDelay>5</RestartDelay>
<RestartCount>2</RestartCount>
<ResetRestartCountAfter>86400</ResetRestartCountAfter>
</WatchDog>
</Configuration>
</CEEConfig>
Restart the CEE process:
# /opt/CEEPack/emc_cee_svc restart Shutting down EMC CEE Service: [ OK ] Starting EMC CEE Service: emc_cee.exe (pid 18902 18899) is running... Debug is now enabled. Trigger some auditable events on the cluster or monitor for the error we are troubleshooting then revert back to original. To revert back to original config: First, I like to make a copy of the debug config for future use:
#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.debug Then Copy the original backup back to the main config and restart CEE again
#cp /opt/CEEPack/emc_cee_config.xml.bak /opt/CEEPack/emc_cee_config.xml #/opt/CEEPack/emc_cee_svc restart We want to then gather the log file /opt/CEEPack/emc_cee_svc.log and have that sent in for review.
Additional Information
For CEE on Linux configuration and usage instructions, follow the "Common Event Enabler on Linux" documentation attached.
If a previously made debug copy of the configuration file was made and the original configuration is still present, the debug file can be copied to the main configuration and restart the service (Always back up the current configuration as shown above):
#cp /opt/CEEPack/emc_cee_config.xml.debug /opt/CEEPack/emc_cee_config.xml #/opt/CEEPack/emc_cee_svc restart
Affected Products
PowerScale OneFSProducts
PowerScale OneFSArticle Properties
Article Number: 000009293
Article Type: How To
Last Modified: 20 Nov 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.