NetWorker: Sådan indstilles tidspunktet for loggens overgang/trunkering

Summary: NetWorker: Sådan indstilles loggens rollover eller trunkeringstid.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Behov for at indstille NetWorker-logfilerne til at blive overført dagligt i stedet for at lade dem vokse.

Cause

.

Resolution

Kør nsradmin på serveren:
 

nsradmin -p nsrexecd -s localhost

NetWorker administration program.
Use the "help" command for help, "visual" for full-screen mode.
nsradmin> p type: NSR log



Nuværende indstillinger:
                 

       type: NSR log;
               administrator: root, "user=root,host=server.domain.com";
                       owner: NMC Log File;
             maximum size MB: 2;
            maximum versions: 10;
        runtime rendered log: ;
    runtime rollover by size: Disabled;
    runtime rollover by time: Disabled;
                        name: gstd.raw;
                    log path: /opt/lgtonmc/logs/gstd.raw;

                        type: NSR log;
               administrator: root, "user=root,host=server.domain.com ";
                       owner: NetWorker;
             maximum size MB: 2;
            maximum versions: 10;
        runtime rendered log: ;
    runtime rollover by size: Disabled;
    runtime rollover by time: Disabled;
                        name: daemon.raw;
                    log path: /nsr/logs/daemon.raw;



Sådan opdaterer du klokkeslættet:

nsradmin> update  runtime rollover by time: "17:00"
    runtime rollover by time: "17:00";
Update? y
updated resource id 14.0.236.7.47.0.0.0.11.30.125.83.192.168.123.102(3)
    runtime rollover by time: "17:00";
Update? y
updated resource id 13.0.236.7.47.0.0.0.11.30.125.83.192.168.123.102(3)
nsradmin>



 

Additional Information

Det faktiske tidspunkt, hvor logfilerne roterer, kan være op til en time efter det angivne tidspunkt, fordi logfilernes rotationstid kontrolleres hver time efter NetWorker-start.
I ovenstående eksempel, hvor NetWorker startede ved f.eks. hh:35, sker logrotationen derfor kl. 17:35 dagligt.