NetWorker: NMM Hyper-v flat file restore required parameter for RCT backups

Summary: NMM-Hyper-v-Flat-file-Restore-Required-Parameter-for-RCT-backups

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

NMM Hyper-v Flat filgjenoppretting ville mislykkes med følgende feil:

nsrnmmrc NSR critical 37 Metadata Manager failed to initialize 0.
132938:nsrnmmrc:Fatal error during processing of the Metadata file for savetime -- nsavetime.



 

Cause

Standard gjenoppretting av flat fil er satt til VSS ved hjelp av parameter NSR_SNAP_TYPE.

Feilsøkingsloggen nsrnmmrc viser.
180351: nsrnmmrc: Application Information NSR_SNAP_TYPE=vss or NSR_SNAP_TYPE=rct is not provided, adding NSR_SNAP_TYPE=vss as default it to the parameter list for VSS-based recovery.

Hvis sikkerhetskopiering ble tatt med RCT aktivert, mislykkes gjenopprettingen.

Resolution

Running Flat file restore identify backup was taken RCT or VSS. 

For RCT må du spesifisere følgende. 
NSR_SNAP_TYPE=rct 

MERK: Hvis du vil finne ut hvordan sikkerhetskopien ble tatt, kan du bruke mminfo eller nsrinfo til å validere.


Bruke mminfo:

mminfo -Sot -q SSID=4268368342

Der SSID er metadata SSID APPLICATIONS:\Microsoft Hyper-V\Windows 2016.
Og se etter *NSR_RCT_DISK_RCT_ID:

Bruke nsrinfo:

nsrinfo -v -n nmm_bbb Clustername >C:\nsrinfo.txt

Og se etter NSR_RCT_BACKUP: TRUE;

Affected Products

NetWorker Module for Microsoft

Products

NetWorker, NetWorker Module for Microsoft
Article Properties
Article Number: 000170182
Article Type: Solution
Last Modified: 21 Jan 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.