VNXe3200: DAE disk failure also generates DAE failure alert
Summary: On VNXe3200, a Disk Array Enclosure (DAE) disk failure triggers a DAE failure alert, generating log entries for resynchronizing.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Different from VNXe1 series products (VNXe3100/3150/3300), DAE disk failure in VNXe3200 also generates DAE failure alert.
"2017-06-17T00:46:15.998Z" "XXX" "Neo_CEM" "15464" "N/A" "WARN" "14:6025c" :: "DAE 0 1 Disk 1 is resynchronizing with the system" :: Category=User Component=Health "2017-06-17T00:47:15.940Z" "XXX" "Neo_CEM" "15464" "N/A" "INFO" "14:6025b" :: "DAE 0 1 Disk 1 is operating normally" :: Category=User Component=Health
This alert is automatically cleared after disk replacement.
"2017-08-24T07:45:12.084Z" "XXX" "Neo_CEM" "12708" "N/A" "INFO" "14:60268" :: "DAE 0 1 Disk 1 has been removed." :: Category=User Component=Health "2017-08-24T07:45:12.365Z" "XXX" "Neo_CEM" "12708" "N/A" "INFO" "14:60198" :: "DAE 0 1 is operating normally" :: Category=User Component=Health
Cause
No Cause
Resolution
DAE failure alert gets cleared after disk replacement, so no need for other special operation.
If DAE still shows faults after disk replacement, contact Dell Technologies for further troubleshooting.
Affected Products
VNXe3200Products
VNXe3200Article Properties
Article Number: 000051931
Article Type: Solution
Last Modified: 11 Mar 2026
Version: 4
Find answers to your questions from other Dell users
Support Services