PowerEdge:M1000e AG 交換器連接埠處於 persistentdisable 狀態,並顯示錯誤:「組態不具備」
Summary: PowerEdge M1000e:處於 persistentdisable 狀態的 AG 交換器連接埠。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
影響:
F 連接埠輸入 persistentdisable 狀態,且無法變更為啟用狀態。
環境:
存取閘道模式
的 Dell PowerEdge M1000e
Brocade M6505問題:
F 連接埠停滯在持續停用狀態。
接入閘道重新啟動后,埠更改為持續禁用狀態。
範例:
switchshow : switchName: switchname switchType: 130.0 switchState: Online switchMode: Access Gateway Mode switchWwn: 10:00:00:00:00:00:00:00 switchBeacon: OFF Index Port Address Media Speed State Proto ================================================== <truncated> 6 6 010600 cu N16 In_Sync FC Disabled (Persistent) 7 7 010700 cu N16 Online FC F-Port <pwwn> 8 8 010800 cu N16 In_Sync FC Disabled (Persistent)
嘗試變更為 persistentenabling 連接埠數量:
switchname:admin> portcfgpersistentenable 8 Port 8: portcfgpersistentenable failed. Configuration is not capable(8).
Cause
連接埠卡在 persistentdisable 組態。
Resolution
程序:
- 收集
ag --mapshow output以查看 F 連接埠對應到哪個 N 連接埠的位置。 - 使用以下命令將連接埠設回原廠預設值
<portcfgdefault (port no) >。
範例: portCfgDefault 8
- 使用命令「switchshow 」檢查連接埠狀態 如果連接埠不在
persistentdisable州。
範例:之後
portcfgdefault 命令,狀態變更為: In_Sync FC Disabled (No mapping for F-Port)
- 使用下列命令啟用連接埠:
portenable (port no)。 - 使用命令將連接埠對應回原始的 N 連接埠:
ag –mapadd (n-port) (f-port)。
範例:
ag --mapadd 20 "8"
- 使用以下命令檢查連接埠是否已對應至 N 連接埠:
ag --mapshow。 - 使用以下命令檢查連接埠狀態:
switchshow。預計埠處於連線狀態。
範例:
Online FC F-Port
Affected Products
Brocade M6505, PowerEdge M1000EArticle Properties
Article Number: 000185988
Article Type: Solution
Last Modified: 12 Jun 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.