VxRail: Upgrade serveru VMware vCenter při exportu dat ze zdrojového virtuálního počítače se nezdařil

Summary: Během upgradu softwaru VxRail VCenter došlo k selhání exportu dat ze zdrojového serveru vCenter na cílový server vCenter. Z protokolu je patrné, že mnoho času bylo věnováno exportu dat služby VMware Analytics. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Z platformy VxRail lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
        at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
        at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
        at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
        at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
        at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
        at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
        at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
        at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
        at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
        at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
        at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
        at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
        at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
        ... 7 common frames omitted
Ze strany /var/log/vmware/upgrade/export.json nově vyvinutého serveru vCenter, upgrade se nezdařil, když "Exporting VMware Analytics Service data..." s TIME_OUT Error:
{
    "progress": 37,
    "progress_message": {
        "id": "ur.upgrade.script.export.progress.text",
        "translatable": "Exporting %(0)s data...",
        "args": [
            "VMware Analytics Service"
        ],
        "localized": "Exporting VMware Analytics Service data..."
    },
    "status": "error",
    "info": [],
    "warning": [],
    "question": null,
    "error": {
        "detail": [
            {
                "id": "ur.upgrade.execution.timedout.text",
                "translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
                "args": [
                    60,
                    60
                ],
                "localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
            }
        ],
        "componentKey": "upgrade_framework",
        "problemId": null,
        "resolution": {
            "id": "ur.upgrade.execution.timedout.resolution",
            "translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and  %(2)s for import historical data phase. The timeout is in minutes.",
            "args": [
                "UPGRADE_EXPORT_TIMEOUT",
                "UPGRADE_IMPORT_TIMEOUT",
                "UPGRADE_POST_IMPORT_TIMEOUT"
            ],
            "localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and  UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
        }
    },

Cause

K tomuto problému dochází, protože proces telemetrie odesílání odesílá nadměrný počet požadavků s jedinečnými ID, což vede k vytvoření mnoha souborů v "/var/log/vmware/analytics/prod" adresář. Někdy to vedlo k nahromadění 185 000 až 375 000 souborů.

Resolution

Viz článek KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (externí odkaz)

  1. Připojte se ke zdrojovému serveru vCenter pomocí SSH
  2. Spuštěním následujícího příkazu zkontrolujte počet souborů vytvořených na serveru vCenter kvůli procesu odesílání telemetrie: ls /var/log/vmware/analytics/prod | wc -l
  3. Stáhněte si cleaning_vddk_script.sh skript z části Přílohy tohoto článku.
  4. Nahrajte skript do nástroje vCenter a přiřaďte oprávnění ke spuštění pomocí tohoto příkazu: chmod +x cleaning_vddk_script.sh
  5. Spusťte skript: ./cleaning_vddk_script.sh
  6. Restartujte upgrade z doplňku VxRail.