VxRail: VMware vCenter -palvelimen päivitys epäonnistui, kun tietoja viedään lähdevirtuaalikoneesta
Summary: VxRail VCenterin päivitys epäonnistui, kun tietoja vietiin vCenter-lähdepalvelimesta vCenter-kohdepalvelimeen. Lokista näkyy, että VMware Analytics Service -palvelun tietojen viemiseen käytettiin paljon aikaa. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
VxRailista
lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted Alkaen /var/log/vmware/upgrade/export.json äskettäin kehitetyn vCenter-palvelimen loki, päivitys epäonnistui, kun"Exporting VMware Analytics Service data..." kanssa TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Tämä ongelma ilmenee, koska push-telemetriaprosessi lähettää liian suuren määrän pyyntöjä yksilöllisillä tunnuksilla, mikä johtaa monien tiedostojen luomiseen "/var/log/vmware/analytics/prod" hakemisto. Joskus tämä on johtanut 185 000–375 000 tiedoston kertymiseen.
Resolution
Katso KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (ulkoinen linkki)
- Muodosta SSH-yhteys vCenter-lähdepalvelimeen
- Tarkista vCenter-palvelimeen push-telemetriaprosessin ansiosta luotujen tiedostojen määrä seuraavalla komennolla:
ls /var/log/vmware/analytics/prod | wc -l - Lataa
cleaning_vddk_script.shScript tämän artikkelin Liitteet-osiosta . - Lataa komentosarja vCenteriin ja määritä suorita-oikeudet seuraavalla komennolla:
chmod +x cleaning_vddk_script.sh - Suorita komentosarja:
./cleaning_vddk_script.sh - Käynnistä päivitys uudelleen VxRail-laajennuksesta.
Affected Products
VxRail, VxRail Appliance SeriesArticle Properties
Article Number: 000372265
Article Type: Solution
Last Modified: 31 Oct 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.