Summary: Under en oppgradering av VxRail VCenter mislyktes den ved eksport av data fra source-vCenter-serveren til vCenter-målserveren. Fra loggen viser det at mye tid ble brukt på "Eksportere VMware Analytics Service-data." ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Fra VxRail
lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted Fra /var/log/vmware/upgrade/export.json logg av den nyutviklede vCenter-serveren, mislyktes oppgraderingen når "Exporting VMware Analytics Service data..." med TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Dette problemet oppstår fordi push-telemetriprosessen sender for mange forespørsler med unike IDer, noe som fører til at det opprettes mange filer i "/var/log/vmware/analytics/prod" katalog. Noen ganger har dette ført til akkumulering av 185 000 til 375 000 filer.
Resolution
Se KB-https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (ekstern lenke)
- Koble til kilden vCenter-server ved hjelp av SSH
- Kjør følgende kommando for å kontrollere antall filer som er opprettet på vCenter-serveren på grunn av push-telemetriprosessen:
ls /var/log/vmware/analytics/prod | wc -l - Last ned
cleaning_vddk_script.shskript fra vedleggsdelen i denne artikkelen. - Last opp skriptet til vCenter, og tilordne "run"-tillatelser med denne kommandoen:
chmod +x cleaning_vddk_script.sh - Kjør skriptet:
./cleaning_vddk_script.sh - Start oppgraderingen på nytt fra VxRail-pluginet.