VxRail: Det gick inte att uppgradera VMware vCenter-servern vid export av data från den virtuella källdatorn
Summary: Under en uppgradering av VxRail VCenter misslyckades det vid export av data från vCenter-källservern till vCenter-målservern. Av loggen framgår att mycket tid har lagts på att exportera VMware Analytics Service-data. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Från VxRail
lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted Från /var/log/vmware/upgrade/export.json loggen för den nyutvecklade vCenter-servern, misslyckades uppgraderingen när "Exporting VMware Analytics Service data..." med TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Det här problemet beror på att push-telemetriprocessen skickar ett stort antal begäranden med unika ID:n, vilket resulterar i att många filer skapas i "/var/log/vmware/analytics/prod"-katalogen. Ibland har detta lett till ackumulering av 185 000 till 375 000 filer.
Resolution
Se KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (Extern länk)
- Ansluta till vCenter-källservern med SSH
- Kör följande kommando för att kontrollera antalet filer som skapats på vCenter-servern på grund av push-telemetriprocessen:
ls /var/log/vmware/analytics/prod | wc -l - Ladda ner
cleaning_vddk_script.shskript från avsnittet Bifogade filer i den här artikeln. - Ladda upp skriptet till vCenter och tilldela körbehörigheter med det här kommandot:
chmod +x cleaning_vddk_script.sh - Kör skriptet:
./cleaning_vddk_script.sh - Starta om uppgraderingen från VxRail-insticksprogrammet.
Affected Products
VxRail, VxRail Appliance SeriesArticle Properties
Article Number: 000372265
Article Type: Solution
Last Modified: 31 Oct 2025
Version: 3