The expanded virtual-volume was presented to cross-connected hosts with different LUN IDs. (Refer to the host.txt file which can be found in the base collect-diagnostics (c-d) file under analysis notes directory) **************************************** * Cluster Name: cluster-1 * **************************************** --------------------------------------------- View Name: Test_Storage_View View Status: ok --------------------------------------------- LUN-4: TestVolume (VPD83T3:60001440000000xxxxxxxxxxxxxxxx) ==> device_TestVolume (distributed raid-1) cluster-1: ==> device_TestVolume (raid-0) ==> extent_TestVolume ==> TestVolume ==> VPD83T3:60060160xxxxxxxxxxxxxxxxxx ==> EMC~CLARiiON~xxxxxxxxxxxxxxx (EMC~CLARiiON) cluster-2: ==> device_TestVolume_1 (raid-0) ==> extent_device_TestVolume_1 ==> TestVolume_1 ==> VPD83T3:600601604xxxxxxxxxxxxxxxxxx ==> EMC~CLARiiON~xxxxxxxxxxxxxxx (EMC~CLARiiON) **************************************** * Cluster Name: cluster-2 * **************************************** --------------------------------------------- View Name: Test_Storage_View View Status: ok --------------------------------------------- LUN-6: TestVolume (VPD83T3:60001440000000xxxxxxxxxxxxxxxx) ==> device_TestVolume (distributed raid-1) cluster-1: ==> device_TestVolume (raid-0) ==> extent_TestVolume ==> TestVolume ==> VPD83T3:60060160xxxxxxxxxxxxxxxxxx ==> EMC~CLARiiON~xxxxxxxxxxxxxxx (EMC~CLARiiON) cluster-2: ==> device_TestVolume_1 (raid-0) ==> extent_device_TestVolume_1 ==> TestVolume_1 ==> VPD83T3:600601604xxxxxxxxxxxxxxxxxx ==> EMC~CLARiiON~xxxxxxxxxxxxxxx (EMC~CLARiiON) As shown above, the same-virtual-volume was exported to cross-connected storage-view with different LUN IDs on cluster-1 and cluster-2. |