Connectrix B-Serien: Bryterkjernepanikk på grunn av at weblinker-bakgrunnsprosessen øker minnebruken

Summary: Svitsjen rapporterte om et MEMORY_USAGE_STATE problem, og etter 30 minutter startet svitsjen på nytt på grunn av kjernepanikk.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Fra errdump ytelse:

2025/07/22-22:50:19 (CST), [MAPS-1003], 293324, SLOT 2 | FID 128, WARNING, CC-MA001-SANX7-1, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-22:52:19 (CST), [MAPS-1003], 293331, SLOT 2 | FID 81, WARNING, CC-MA001-SANX7-1-81, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-23:10:09 (CST), [EM-1033], 156895, SLOT 1 | CHASSIS, ERROR, nevccsg31swb01, CP in Slot 2 set to faulty because CP ERROR asserted.

2025/07/22-23:10:09 (CST), [EM-1047], 156896, SLOT 1 | CHASSIS, INFO, nevccsg31swb01, CP in slot 2 not faulty, CP ERROR deasserted.

2025/07/22-23:11:19 (CST), [HAM-1004], 293376, SLOT 2 | CHASSIS, INFO, nevccsg31swb01, Processor rebooted - Software Fault:Kernel Panic

Cause

Bryteren har oppdaget FOS-863077 , og denne feilen forårsaker en minnelekkasje.

Symptom:
Den weblinker daemon Minnebruken fortsetter å øke under SANnav-overvåking, og aktiviteter som configupload Begynn å mislykkes. 

Gjeldende svitsjversjon Fabric OS 9.2.2 har ikke reparasjonen. Kunden bruker et tredjeparts overvåkingsverktøy som også er berørt.

SRM-5011-feilene som viser at den nådde 75% av grensen fra 21. juli 2025, så det tok 1 dag derfra til failover:

2025/07/21-18:19:43:390633 (CST), [SRM-5011], 2330474/0, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, phy memory utilization meets or exceeds threshold of 75 percent. Current value is 76 percent., osmisc.c, line: 405, comp:osmiscd, ltime:2025/07/21-18:19:43:390406

Og sett, det er mange LDAP-påloggingsfeilmeldinger. Fordi alle påloggingsfeilene er fra HTTPS, bruker de weblinker prosess. De tapper de tilgjengelige weblinker minne til det tømmes helt og forårsaker en kjernepanikk for å gjenopprette.  

2025/07/22-23:06:26:207115 (CST), [SEC-1347], 2336526/293364, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-23:06:26:206934

2025/07/22-23:06:26:207828 (CST), [SEC-1193], 2336527/293365, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, Security violation: Login failure attempt via HTTPS. IP Addr: 10.236.90.16., public.c, line: 4039, comp:weblinker, ltime:2025/07/22-23:06:26:207430

2025/07/22-23:07:12:879161 (CST), [SEC-1347], 2336528/293366, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-

Resolution

På 7. generasjonssystemer er strømningsmonitoren aktivert som standard. Hvis en svitsj som kjører FOS v9.1.0 eller nyere, deaktiverer flytovervåking, kan imidlertid dette problemet bli utsatt. Dette problemet kan også bli eksponert på Gen6-plattformer uten Flow Vision-lisens installert.

Løsning:
Aktiver flytovervåking:

 flow --activate sys_flow_monitor

På Gen6-systemer uten Flow Vision-lisens må du oppgradere til en FOS-versjon med en løsning på dette problemet.

  • FOS9.1.1d6RN-lukket 
  • FOS9.2.0c3RN-lukket 
  • FOS9.2.1bRN-lukket 
  • FOS9.2.2aRN-lukket 