Connectrix B-Series:由於 Weblinker 精靈記憶體使用量增加,導致交換器核心錯誤

Summary: 交換器回報MEMORY_USAGE_STATE問題,30 分鐘後,交換器因核心錯誤而重新開機。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

errdump 產量:

2025/07/22-22:50:19 (CST), [MAPS-1003], 293324, SLOT 2 | FID 128, WARNING, CC-MA001-SANX7-1, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-22:52:19 (CST), [MAPS-1003], 293331, SLOT 2 | FID 81, WARNING, CC-MA001-SANX7-1-81, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-23:10:09 (CST), [EM-1033], 156895, SLOT 1 | CHASSIS, ERROR, nevccsg31swb01, CP in Slot 2 set to faulty because CP ERROR asserted.

2025/07/22-23:10:09 (CST), [EM-1047], 156896, SLOT 1 | CHASSIS, INFO, nevccsg31swb01, CP in slot 2 not faulty, CP ERROR deasserted.

2025/07/22-23:11:19 (CST), [HAM-1004], 293376, SLOT 2 | CHASSIS, INFO, nevccsg31swb01, Processor rebooted - Software Fault:Kernel Panic

Cause

交換器遇到 FOS-863077 和此缺陷導致記憶體流失。

症狀:
weblinker daemon 在 SANnav 監控期間,記憶體使用量會持續增加,以及諸如 configupload 開始失敗。

目前的交換器版本 Fabric OS 9.2.2 沒有修正程式。客戶正在使用第三方監控工具,該工具也會受到影響。

SRM-5011 錯誤顯示其從 2025 年 7 月 21 日開始已達到限制的 75%,因此需要 1 天才能進行容錯移轉:

2025/07/21-18:19:43:390633 (CST), [SRM-5011], 2330474/0, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, phy memory utilization meets or exceeds threshold of 75 percent. Current value is 76 percent., osmisc.c, line: 405, comp:osmiscd, ltime:2025/07/21-18:19:43:390406

可以看到有許多 LDAP 登入失敗訊息。由於所有登入失敗均來自 HTTPS,因此他們使用 weblinker 過程。他們正在耗盡可用的資源 weblinker 記憶體,直到它完全耗盡並導致內核崩潰恢復。  

2025/07/22-23:06:26:207115 (CST), [SEC-1347], 2336526/293364, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-23:06:26:206934

2025/07/22-23:06:26:207828 (CST), [SEC-1193], 2336527/293365, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, Security violation: Login failure attempt via HTTPS. IP Addr: 10.236.90.16., public.c, line: 4039, comp:weblinker, ltime:2025/07/22-23:06:26:207430

2025/07/22-23:07:12:879161 (CST), [SEC-1347], 2336528/293366, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-

Resolution

默認情況下,在 Gen7 系統上,流量監視器處於啟用狀態。但是,如果任何執行 FOS v9.1.0 或更新版本的交換器停用流量監控,則可能會暴露此問題。在未安裝 Flow Vision 授權的 Gen6 平台上也可能會出現此問題。

因應措施:
啟動流量監控器:

 flow --activate sys_flow_monitor

在無 FlowVision 授權的 Gen6 系統上,升級至具有此問題修正的 FOS 版本。

  • FOS9.1.1d6RN - 已關閉 
  • FOS9.2.0c3RN 關閉 
  • FOS9.2.1bRN - 已關閉 
  • FOS9.2.2aRN 關閉 