PowerFlex:SDC 錯誤:無法擷取插槽的插槽本機位址

Summary: 節點重新開機後,在 /var/log/messages 中發現 SDC 錯誤,並顯示「無法擷取插槽的插槽本機位址」。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

/var/log/messages 將在節點重新開機時回報以下錯誤:

Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 0000000036f5061f with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000478b06fd with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000ec72fcc2 with Errno 16
Mar  6 16:08:16 host1 kernel: PowerFlex netSock_GetMyAddress:1776 :Error: Failed to retrieve socket local address for socket 00000000248b334d with Errno 16

 

影響 

沒有影響;回報的錯誤是表面的。 

Cause

此問題的原因是,在節點重新開機後,連接埠擺動報告給 MDM 時,代碼中遺漏了 SDC 的本機插槽位址。

儘管此錯誤被歸類為外觀錯誤,但它不會影響 MDM 的過程,因為它不使用這些位址。因此,不會影響系統的性能或功能。

Resolution

忽略 /var/log/messages 中的錯誤,直到叢集升級到下方的修正版本。

受影響的版本

PowerFlex SDC 3.6.3

PowerFlex SDC 4.x

已修正問題的版本

PowerFlex SDC 3.6.4

PowerFlex SDC 4.5.3

Affected Products