NVP-vProxy:备份失败,并显示“虚拟机备份请求无效”
Summary: 反复重试后,NetWorker VMware Protection (NVP) vProxy 备份失败,并显示“虚拟机备份请求无效”。NetWorker 服务器报告 Data Domain (DD) 已达到其最大读取流计数。DD 读取流耗尽会阻止在 NetWorker 存储节点上建立新的备份会话。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
NetWorker VMware 保护集成配置了 vProxy Appliance。备份已成功运行一段时间,然后开始间歇性失败,并显示”
VMware 保护策略备份操作日志中一个虚拟机故障的示例:
The VM backup request is not valid.“备份操作日志显示,在一小时内不断重试直接保存到 NetWorker 存储节点,然后失败并显示消息。
VMware 保护策略备份操作日志中一个虚拟机故障的示例:
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR notice Action backup vmware-vproxy 'backup' has initialized as 'vproxysave job' with job id 2370140 ... MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR notice Saving the backup data in the pool 'Prod VM'. MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR notice Received the media management binding information on the host '[NETWORKER_STORAGE_NODE]'. MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR notice Connected to the nsrmmd process on the host '[NETWORKER_STORAGE_NODE]'. MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR warning Unable to set up the direct save with server '[NETWORKER_STORAGE_NODE]': retry needed. ... MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR error Unable to process VM '[VM_NAME]': Request timed out before session established. ... MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR warning Unable to set up the direct save with server '[NETWORKER_STORAGE_NODE]': The VM backup request is not valid.. MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR critical [VM_NAME]: Cannot start session with NetWorker server '[NETWORKER_STORAGE_NODE]': The VM backup request is not valid.. ... MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrvproxy_save NSR notice Action backup vmware-vproxy 'backup' with job id 2370140 is exiting with status 'failed', exit code 1The
deamon.raw 显示在工作流开始时,NetWorker 服务器生成警告,指示 Data Domain 已到达 read stream 计数限制。在 VMware 保护策略执行期间,NetWorker 服务器 daemon.raw 显示
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR info Protection Policy Notice: Starting workflow '[POLICY_NAME]/[WORKFLOW_NAME]'
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR info Protection Policy Notice: Starting action 'backup' for workflow '[POLICY_NAME]/[WORKFLOW_NAME]'
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR warning current_read_stream (89) reach max_read_stream 50 for DDR '[DATA_DOMAIN]'.
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR warning current_read_stream (90) reach max_read_stream 50 for DDR '[DATA_DOMAIN]'.
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR warning current_read_stream (90) reach max_read_stream 50 for DDR '[DATA_DOMAIN]'.
...
MM/DD/YYYY HH:MM:SS [NETWORKER_SERVER] nsrd NSR info policy notice: action backup failed
Cause
在工作流执行期间,NetWorker 存储节点或目标 DD 过载。DD 强制实施最大读取流计数。当前流计数超过此限制时,DD 无法接受新会话。vProxy 备份过程需要存储节点上的直接保存会话。存储节点无法建立会话,因为 DD 报告已达到流限制。备份会在超时之前重试大约一小时。当多个备份工作流针对同一 DD 同时运行时,通常会发生这种情况。传统客户端备份和 VMware 保护工作流争用相同的 DD 读取流。
Resolution
- 错开备份计划。调整保护策略计划以在一天中分配负载。将传统客户端工作流与 VMware 保护工作流分离。
- 查看 DD 流利用率。在峰值备份窗口期间监视 DD 读取流计数。确定哪些工作流重叠且占用的流最多。
- 减少并发备份会话。降低针对同一 DD 的备份策略的并行度设置。这样可以减少同时流的数量。
- 跨存储节点分布工作负载。如果有多个存储节点可用,请跨不同的存储节点分发 VMware 和传统客户端备份。
- 验证 DD 流限制。查看 DD 许可证和配置以了解最大读取流计数。确认限制符合环境要求。
Article Properties
Article Number: 000053641
Article Type: Solution
Last Modified: 04 Sept 2026
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.