PowerFlex 3.x: Præsentationsserveren holder op med at logføre beskeder i brugergrænsefladen.

Summary: Præsentationsserveren holder op med at logføre beskeder i brugergrænsefladen.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

I dette scenarie installeres præsentationsserveren (mgmt-server) på en SDS-node.

Hændelser fra Primary Meta Data Manager (MDM) angiver, at SDS, som mgmt-serveren er installeret på, placeres i vedligeholdelsestilstand og genstartes.
 

2023-07-19 23:39:45.351000:0237719:MDM_CLI_CONF_COMMAND_RECEIVED    INFO     Command enter_maintenance_mode received, User: ': user-a'. [3246236] SDS: ID: 7fcf39320000000c;
2023-07-19 23:40:02.906000:0237721:SDS_DECOUPLED                    ERROR    SDS: sds-03 (id: 7fcf39320000000c) decoupled.
2023-07-19 23:58:58.776000:0237726:SDS_RECONNECTED                  INFO     SDS: sds-03 (ID 7fcf39320000000c) reconnected.

 

Indvirkning:
Advarsler vises ikke i brugergrænsefladen.

/var/log/messages viser, at noden genstartes.
 

Jul 19 23:47:27 sds-03 systemd-shutdownd: Shutting down at Wed 2023-07-19 23:48:27 BST (reboot)...

Når noden starter op, starter mgmt-servertjenesten, men mislykkes, når du forsøger at starte Alert Manager-tjenesten. 

Den scaleio.log fra mgmt-serveren kan vise følgende fejl.
 

2023-07-19 23:58:39,662 [main|INFO |com.emc.vxflexos.webui.backend.Server.main] Starting PowerFlex MGMT server...
2023-07-19 23:58:44,796 [main|INFO |com.emc.vxflexos.webui.backend.services.ServicesModule.lambda$null$1] Registering service AlertsManagerService to ServiceManager
2023-07-19 23:58:45,804 [AlertsManagerService STARTING|INFO |com.emc.vxflexos.webui.backend.services.alerts.AlertsManagerService.lambda$new$2] Alerts observable got subscribed
2023-07-19 23:58:45,811 [RxSingleScheduler-1|ERROR|com.emc.vxflexos.webui.backend.services.alerts.AlertsManagerService.onError] Error occurred:
java.util.ConcurrentModificationException: null
    at java.util.HashMap.computeIfAbsent(HashMap.java:1135) ~[?:?]
    at com.slimgears.util.autovalue.annotations.PropertyMeta$1.getAnnotation(PropertyMeta.java:130) ~[auto-value-utils-annotations-0.7.46.jar:?]
    at com.slimgears.util.autovalue.annotations.PropertyMeta.hasAnnotation(PropertyMeta.java:76) ~[auto-value-utils-annotations-0.7.46.jar:?]
    at com.slimgears.rxrepo.util.PropertyExpressions.lambda$mandatoryProperties$13(PropertyExpressions.java:267) ~[rxrepo-core-0.7.130.jar:?]
...

Cause

Efter en nodegenstart viser præsentationsserveren muligvis ikke advarsler. Dette sporadiske problem ser ud til at være forbundet med timing eller en løbstilstand under nodens opstart.
 

 

Resolution

Du kan løse problemet ved at genstarte mgmt-server-tjenesten for at få advarslerne tilbage.

systemctl restart mgmt-server.service


 

Påvirkede versioner

PowerFlex 3.6.3 og derunder

Fast i version

PowerFlex 3.6.4


 

Additional Information

Affected Products

PowerFlex Appliance
Article Properties
Article Number: 000220904
Article Type: Solution
Last Modified: 25 Jun 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.