Dell Unity:FAST 快取記憶體在 FAST 快取組態中不可見
Summary: 設定 FAST 快取時,看不到 Dell Unity FAST 快取固態硬碟 (SSD)。(錯誤代碼:0x67001a7)
Symptoms
UEMCLI
磁碟機在 FAST 快取中顯示為不可用或無效使用:
16:48:14 service@UnityXT spb:~/user# uemcli /stor/config/dg show
1: ID = dg_16 Drive type = SAS FAST Cache = no Drive size = 590894538752 (550.3G) Vendor size = 600.0G Rotational speed = 10000 rpm Number of drives = 12 Unconfigured drives = 0 Capacity = 7090734465024 (6.4T) Recommended number of spares = 0
嘗試設定 FAST 快取失敗:
16:48:37 service@UnityXT spb:~/user# uemcli /stor/config/fastcache create -diskGroup dg_16 -drivesNumber 2
Operation failed. Error code: 0x67001a7Specified disk group is not allowable for FAST Cache on the running platform. (Error Code:0x67001a7)
Unisphere
Unisphere > 設定 > 儲存裝置組態 > FAST 快取 > 建立
Cause
有時,問題出在管理方面,重新啟動 Unity 管理服務可解決此問題。
但是,這也可能是真正的錯誤,可能是因為設置或驅動器不相容。
Resolution
如需如何重新啟動 Unity 管理服務的指南,請參閱 Dell 知識文章:
service@(none) spa:~> uemcli /stor/config/dg show
ID = dg_2
Drive type = SAS Flash 2
FAST Cache = yes <<<<<<<<<<<<<<<<<<<<<<<<
Drive size = 196971960832 (183.4G)
Vendor size = 200.0G
Rotational speed = 0 rpm
Number of drives = 3
Unconfigured drives = 3
Capacity = 590915882496 (550.3G)
Recommended number of spares = 1
請參閱下列 Dell 知識文章和白皮書,以確認目前的設定適用於建立 FAST 快取。
- Dell Unity™ 系列設定集區 5.x 版 (2024 年 9 月)
- Dell Unity™ 系列 Unisphere® 命令行介面使用者指南 5.5.1 版 (2025 年 7 月)
- Dell 儲存裝置相容性比較表支援政策聲明
- Dell EMC Unity:FAST 技術概觀 (2021 年 2 月)
- Dell Unity:基本 FAST 快取管理