VNX: server_df comando falha
Summary: VNX: server_df comando falha
Symptoms
O comando 'server_df server_2' falha com "Erro 2: server_2 : Nenhum arquivo ou diretório apresentou falha ao concluir o comando":
[nasadmin@ssgnas03cs0 ~]$ server_df server_2 server_2 : Error 2: server_2 : No such file or directory failed to complete command
As verificações de integridade pré-upgrade falham com os seguintes erros:
Blades : Check if root filesystem is too large Error HC_DM_14505148436: Output from command "/nas/bin/server_df server_2" has no information on file system root_fs_2 Blades : Check if root filesystem has enough free space Error HC_DM_14505148440: Output from command "/nas/bin/server_df server_2" has no information on file system root_fs_2 Blades : Check if file system usage is under limit Error HC_DM_14505148563: Could not determine available disk space for the mounted file systems on the following Blades: * server_2
Todos os outros comandos server_df funcionam com sucesso em outros movimentadores de dados:
[nasadmin@ssgnas03cs0 ~]$ server_df server_3 server_3 : Filesystem kbytes used avail capacity Mounted on root_fs_common 15368 5280 10088 34% /.etc_common root_fs_3 258128 6184 251944 2% /
Cause
A causa raiz nesse caso foi que o file system raiz do server_2 foi desmontado.
[nasadmin@ssgnas03cs0 ~]$ server_mount ALL server_2 : <------ nothing mounted server_3 : root_fs_3 on / uxfs,perm,rw root_fs_common on /.etc_common uxfs,perm,ro
Ao listar todos os sistemas de arquivos, ficou claro que o sistema de arquivos raiz "root_fs_2" de server_2 estava listado como não em uso porque foi desmontado.
[nasadmin@ssgnas03cs0 ~]$ nas_fs -l id inuse type acl volume name server 1 n 1 0 10 root_fs_1 2 y 1 0 40 root_fs_common 3,2 3 n 5 0 73 root_fs_ufslog 4 n 5 0 76 root_panic_reserve 5 n 5 0 93 root_fs_d3 6 n 5 0 94 root_fs_d4 7 n 5 0 95 root_fs_d5 8 n 5 0 96 root_fs_d6 9 n 1 0 12 root_fs_2 <------------ inuse = n 10 y 1 0 14 root_fs_3 2
Resolution
Antes de o cliente solicitar assistência do suporte, uma reinicialização do Data Mover era concluída e nenhuma melhoria era observada. Para resolver esse problema, faça log-in como usuário "root" na Control Station primária e monte novamente o "root_fs_2" do file system no Data Mover server_2:
[root@ssgnas03cs0 nasadmin]# server_mount server_2 root_fs_2 / server_2 : done
Certifique-se de que o file system raiz seja remontado:
[root@ssgnas03cs0 nasadmin]# server_mount ALL server_2 : root_fs_2 on / uxfs,perm,rw root_fs_common on /.etc_common uxfs,perm,ro server_3 : root_fs_3 on / uxfs,perm,rw root_fs_common on /.etc_common uxfs,perm,ro
Depois que o file system raiz for montado, execute o comando "server_df server_2" para garantir que ele seja concluído com sucesso:
[root@ssgnas03cs0 nasadmin]# server_df server_2 server_2 : Filesystem kbytes used avail capacity Mounted on root_fs_common 15368 5280 10088 34% /.etc_common root_fs_2 258128 6264 251864 2% /
Additional Information
Nesse caso específico, o cliente estava realizando uma limpeza de file systems desnecessários para recuperar espaço para o pool de NAS. Como parte da limpeza, eles desmontaram permanentemente e tentaram excluir o "root_fs_2" do file system raiz do Data Mover server_2. O file system raiz de um Data Mover nunca deve ser excluído.