Connectrix B-Series: Detected termination of process "emd"
Summary: Detected multiple termination of process "emd".
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The following message appears in both the "Errdump" and "RAS" logs:
2016/03/11-16:29:56:564954, [KSWD-1002], 621992/614333, SLOT 7 | FFDC | CHASSIS, WARNING, switchname, Detected termination of process emd:<pid>.
Cause
Brocade defect DEFECT000569678.
This occurs when polling scripts send large amount of "portshow" commands to the "emd" process in a short burst of time.
Example queries seen in "clihistory":
Fri Mar 11 19:55:00 2016 switchname, admin, portshow 8/1
Fri Mar 11 19:55:01 2016 switchname, admin, portshow 8/0
Fri Mar 11 19:55:01 2016 switchname, admin, portshow 8/3
Fri Mar 11 19:55:02 2016 switchname, admin, portshow 8/2
Fri Mar 11 19:55:03 2016 switchname, admin, portshow 8/5
Fri Mar 11 19:55:03 2016 switchname, admin, portshow 8/4
Fri Mar 11 19:55:04 2016 switchname, admin, portshow 8/7
Fri Mar 11 19:55:04 2016 switchname, admin, portshow 8/6
This occurs when polling scripts send large amount of "portshow" commands to the "emd" process in a short burst of time.
Example queries seen in "clihistory":
Fri Mar 11 19:55:00 2016 switchname, admin, portshow 8/1
Fri Mar 11 19:55:01 2016 switchname, admin, portshow 8/0
Fri Mar 11 19:55:01 2016 switchname, admin, portshow 8/3
Fri Mar 11 19:55:02 2016 switchname, admin, portshow 8/2
Fri Mar 11 19:55:03 2016 switchname, admin, portshow 8/5
Fri Mar 11 19:55:03 2016 switchname, admin, portshow 8/4
Fri Mar 11 19:55:04 2016 switchname, admin, portshow 8/7
Fri Mar 11 19:55:04 2016 switchname, admin, portshow 8/6
Resolution
Workaround:
Modify the scripts to space out such polling bursts over a larger period of time, use port range in "portshow" commands rather than back to back consecutive polls of individual ports.
Permanent Fix:
Upgrade to Fabric OS 7.4.1b and above.
Modify the scripts to space out such polling bursts over a larger period of time, use port range in "portshow" commands rather than back to back consecutive polls of individual ports.
Permanent Fix:
Upgrade to Fabric OS 7.4.1b and above.
Products
Connectrix B-Series Hardware, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8BArticle Properties