Connectrix B-Series: Detected termination of process "emd"

Summary: Detected multiple termination of process "emd".

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



The following message appears in both the "Errdump" and "RAS" logs:

2016/03/11-16:29:56:564954, [KSWD-1002], 621992/614333, SLOT 7 | FFDC | CHASSIS, WARNING, switchname, Detected termination of process emd:<pid>.

Cause

Brocade defect DEFECT000569678.

This occurs when polling scripts send large amount of "portshow" commands to the "emd" process in a short burst of time.

Example queries seen in "clihistory":

Fri Mar 11 19:55:00 2016         switchname, admin, portshow 8/1
Fri Mar 11 19:55:01 2016         switchname, admin, portshow 8/0
Fri Mar 11 19:55:01 2016         switchname, admin, portshow 8/3
Fri Mar 11 19:55:02 2016         switchname, admin, portshow 8/2
Fri Mar 11 19:55:03 2016         switchname, admin, portshow 8/5
Fri Mar 11 19:55:03 2016         switchname, admin, portshow 8/4
Fri Mar 11 19:55:04 2016         switchname, admin, portshow 8/7
Fri Mar 11 19:55:04 2016         switchname, admin, portshow 8/6


Resolution

Workaround:
Modify the scripts to space out such polling bursts over a larger period of time, use port range in "portshow" commands rather than back to back consecutive polls of individual ports.

Permanent Fix:
Upgrade to Fabric OS 7.4.1b and above.

Products

Connectrix B-Series Hardware, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8B
Article Properties
Article Number: 000064818
Article Type: Solution
Last Modified: 25 Apr 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.