PowerFlex: Feil under sikkerhetskopiering utløser ikke et varsel
Summary: Når sikkerhetskopieringen av PowerFlex Manager Platform (PFMP) mislykkes, utløses ingen varsler.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Feil ved PFMP-sikkerhetskopiering utløser ingen varsler i PFMP-brukergrensesnittet. Loggene viser imidlertid en sikkerhetskopieringsfeil:
05:00 stdout F 2025-09-01 17:00:02,239 [JobMgrQuartzScheduler_Worker-49] (LCMService.java:796) [ERROR] Check backup connection failed 2025-09-01T12:00:02.243277548-05:00 stdout F com.dell.asm.i18n2.exception.AsmCheckedException: Could not connect to path specified
2025-09-01T12:00:02.243382794-05:00 stdout F 2025-09-01 17:00:02,242 [JobMgrQuartzScheduler_Worker-49] (ScheduledBackupJob.java:90) [ERROR] Scheduled K8 Backup Job : Failed to run k8 Backup
2025-09-01T12:00:02.243400246-05:00 stdout F com.dell.asm.rest.common.exception.LocalizedWebApplicationException: HTTP 500 Internal Server Error
Fra referanseveiledningen for varsler og hendelser merkes sikkerhetskopieringsfeilene som HOVED- og KRITISKE-nivåer:

Innvirkning
Sikkerhetskopieringsfeil vises ikke i Varsler-delen i brukergrensesnittet.
Cause
Den offisielle dokumentasjonen er korrekt og ble skrevet basert på varslingskravene. Fordi varslingskoden ble implementert feil, sendes ikke varslene som tiltenkt.
Resolution
Ingen løsning er tilgjengelig. Riktig varslingskode implementert i PFMP-versjonen nevnt i delen Løst i versjon
Berørte versjoner
PFMP 4.x
PFMP 5.0
Løst i versjon
PFMP 5.1
Affected Products
PowerFlex rack, ScaleIOArticle Properties
Article Number: 000379439
Article Type: Solution
Last Modified: 13 Oct 2025
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.