Connectrix Brocade: "Processor rebooted - Software Fault:ASSERT"
Resumen: This article explains the workaround when the switch rebooted due to the error "Processor rebooted - Software Fault:ASSERT."
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
Switch rebooted due to the following error:
Processor rebooted - Software Fault:ASSERT
Causa
The "Software Fault:ASSERT" is a software issue and it happened on CP1 (earlier Active) it failed over to the other CP 0 (earlier Standby)
The problem was in the routing services, a null pointer was received while trying to fetch the data.
The problem was in the routing services, a null pointer was received while trying to fetch the data.
Post failover:
Fabric OS: v7.1.1c1 hadump : --------------------------------------- TIME_STAMP: Mar 7 11:23:37.498073 --------------------------------------- Local CP (Slot 6, CP0): Active, Cold Recovered Remote CP (Slot 7, CP1): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized errdump: 2019/03/04-00:22:05, [HAM-1004], 30432, SLOT 7 | CHASSIS, INFO, ED_DCX8510_8B, Processor rebooted - Software Fault:ASSERT. Core.pd file: MSR: 00029200 EE: 1 PR: 0 FP: 0 ME: 1 IR/DR: 0/0 TASK = b06c8e10[1869] 'RTEK_TH' Last syscall: -1 ASSERT - Failed expression: op != NULL, file = /vobs/projects/springboard/build/swbd62/fabos/src/sys/lib/fabos/fabobj_mgr/fabmedia.c, line = 183, kernel mode args = 0 set_reboot_reason reason=Software Fault:ASSERT Kernel panic - not syncing: fabos assertion failed cpu 0: ASSERT - Failed expression: op != NULL, file = /vobs/projects/springboard/build/swbd62/fabos/src/sys/lib/fabos/fabobj_mgr/fabmedia.c, line = 183 args = 0 PD Start PowerPC Book-E Watchdog Shutdown soft timer PLATFORM_FIRST MTRACER mtracer_panicdump mtracer_panicdump write=0x44a1 reboot_reason PD_MISC CONSOLE_LOG 6300 KBytes in 2 file(s) use "supportsave" command to upload
Resolución
A software defect in routing services caused the failure hitting Brocade defect DEFECT000440968.
The fix for the issue is to upgrade the switch to FOS 7.4.x and above.