VNX Unified:VNX-FILE 复制运行状况检查程序 - 用户可更正

Resumen: 本文讨论如何在 VNX-FILE 环境中运行运行状况检查。程序在本地和远程在环境中的所有控制台上运行运行状况检查。此计划重点介绍与复制相关的信息。

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Instrucciones

  1. 将文件上载到 VNX-FILE 控制台。上传文件后,使用以下命令解压缩文件:  
[nasadmin@CS0 tmp]$ tar -xvf KB000479575-IPRep_Health_Check_V1.3.tar
Replication_Health_Check.pl
[nasadmin@CS0 tmp]$ ls -al
-rw-rw-r-- 1 nasadmin nasadmin 112640 Aug 15 08:01 KB000479575-IPRep_Health_Check_V1.3.tar
-rwxrwxr-x 1 nasadmin nasadmin 102131 Aug 15 07:50 Replication_Health_Check.pl
  1. 验证 MD5SUM 是否与以下命令匹配:  
[nasadmin@CS0 tmp]$ md5sum *
d621f3e53770a5b6e1d61590562eb718  KB000479575-IPRep_Health_Check_V1.3.tar
8859de64706171fc19e1d245e7b80670  Replication_Health_Check.pl
[nasadmin@CS0 tmp]$

如何启动运行状况检查
  1. 运行以下命令以启动运行状况检查:  
[nasadmin@CS0 tmp]$ ./Replication_Health_Check.pl -full

此程序需要几分钟才能完成。屏幕上将显示汇总输出,以确认其正在进行。程序完成后,按照有关如何解决发现的任何问题的说明进行操作。

除了屏幕输出之外,还有一个详细的日志文件,该文件在本地创建并存储在控制台上。有关任何错误的更深入的信息,请参阅日志文件。文件名和位置各不相同,并且在程序运行时显示。

添加了一个新内容,以查看系统当前复制会话上的“实时系统性能吞吐量”摘要。这有助于“在高级别”显示系统性能统计信息。

Información adicional

程序使用情况
KBA 479575 - VNX-FILE Replication Health Check
This Health Check program will review local and remote nas_replicate sessions.
This program is designed to be executed on the EMC VNX-FILE control station.

########################################################################
  Usage: ./Replication_Health_Check.pl [ -full | -cs | -inter | -repl | -fs | -debug ]
         -full   : Recommended value, runs checks against all configurations
         -cs    : Validates Control Station (CS-CS) communication
         -inter : Validates local and remote interconnects (This is time consuming)
         -repl  : Reviews Replication related statistics
         -fs     : Reviews File System and CKPT settings
         -perf  : Display Replication Performance Statistics (not a health check)
         -debug : Captures FULL debug information, only use if filing a bug
             EXAMPLE ./Replication_Health_Check.pl -cs
             EXAMPLE ./Replication_Health_Check.pl -full
########################################################################

[nasadmin@CS0 tmp]$

Productos afectados

VNX VG10, VNX VG2, VNX VG8, VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5800, VNX7500, VNX7600, VNX8000
Propiedades del artículo
Número del artículo: 000009093
Tipo de artículo: How To
Última modificación: 03 ene 2024
Versión:  3
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.