Data Domain: DD3300 Disk Beacon
Resumen: This article introduces the 'disk beacon' function for DD3300 systems, brought in with Data domain Operating system (DDOS) 6.2.x. The KB article serves as a guide on how to beacon a disk on the DD3300. ...
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Instrucciones
Summary:
- This article introduces the
disk beaconfunction for DD3300 systems; introduced in DDOS 6.2.x. - The command
disk beacon 1.nis issued (usingSSH/CLI) and results in a disk identification LED flashing on the corresponding disk. - Physical Slot numbering (0-based; 1.0) on the DD3300 does not match to DDOS Slot numbering which starts at 1.1.
- This feature helps with the troubleshooting and replacement of faulty disks on the DD3300.
Applies To:
- DD3300 (>= DDOS 6.2.x)
Solution:
- 12x Front disks (1.1 -> 1.12) or 1x Rear disk (1.13) can be beaconed.
- 4x internal disks (1.15 -> 1.18) do not support beaconing.
- DD-CLI Command Syntax:
-
disk beacon 1.<slot number> OR <serial number>
-
- To stop the Beacon press:
-
Ctrl + C
-
Example:
To beacon disk slot 1.7:
# disk beacon 1.7
Start disk LED beaconing for 1.7 ...
^C
LED beaconing completed.
#
To beacon a disk by serial number:
- Gather the Physical hardware serial number using the
disk show hardware detailedcommand.
# disk show hardware detailed
Physical Hardware
Disk Slot Manufacturer/Model Firmware Serial No. Capacity Type State
(pci/idx)
---- --------- ------------------ -------- -------------- ---------- -------- --------
1.1 0 ST4000NM0295 DT31 ZC11Z1GB 3.64 TiB SAS In Use
1.2 1 ST4000NM0295 DT31 ZC1207Y1 3.64 TiB SAS In Use
1.3 2 ST4000NM0295 DT31 ZC12156M 3.64 TiB SAS In Use
1.4 3 ST4000NM0295 DT31 ZC11Z2G6 3.64 TiB SAS In Use
1.5 4 ST4000NM0295 DT31 ZC12108B 3.64 TiB SAS In Use
1.6 5 ST4000NM0295 DT31 ZC120E4S 3.64 TiB SAS In Use
1.7 6 ST4000NM0295 DT31 ZC11Z17L 3.64 TiB SAS In Use
1.8 7 ST4000NM0295 DT31 ZC1207YX 3.64 TiB SAS In Use
1.9 8 ST4000NM0295 DT31 ZC11Z39H 3.64 TiB SAS In Use
1.10 9 ST4000NM0295 DT31 ZC11Z3NW 3.64 TiB SAS In Use
1.11 10 (absent) (absent) (absent) (absent) (absent) Absent
1.12 11 (absent) (absent) (absent) (absent) (absent) Absent
1.13 12 MZ7KM480HMHQ0D3 GD53 S3BUNX0J600149 447.13 GiB SATA-SSD Non-RAID
---- --------- ------------------ -------- -------------- ---------- -------- --------
- Beacon the disk using the appropriate serial number:
# disk beacon ZC11Z17L
Start disk LED beaconing for 1.7 ...
^C
LED beaconing completed.
#
Información adicional
If a disk beacon is already active on another disk (from another SSH session), then the system prompts to stop the active beacon, as seen here:
# disk beacon 1.13
A beacon command is already running on disk 1.7.
Do you want to terminate it? (yes|no) [yes]: yes
Beacon on disk 1.7 terminated.
Start disk LED beaconing for 1.13 ...
^C
LED beaconing completed.
#
The original SSH session displays the following output:
**** Disk beaconing terminated by another disk beacon operation.
Reference:
Productos afectados
Data DomainProductos
Data Domain, DD3300 AppliancePropiedades del artículo
Número del artículo: 000013951
Tipo de artículo: How To
Última modificación: 06 feb 2026
Versión: 7
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.