PowerProtect Cyber Recovery: Error - "The storage interface name provided for multilink object is not valid"
Resumen: Error when adding an interface to Multilink, stating that the object is invalid.
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
Customer is getting this error when trying to configure multi link.
ERROR: Failed to modify application:<CyberSense Server hostname> The storage interface name vethx.xxx provided for multilink object with storage ID xxxxx is not valid.
Causa
Issue is due to a limitation with the number of interfaces on the vault Data Domain being more than 20.
Resolución
DD ../network/interfaces REST API only returns 20 interfaces by default, this has been extended to 100 in CR Release 19.13.0.3.
Release Notes/Installation guide for multilink configuration prerequisites must be followed to avoid further issues.
Productos afectados
Cyber Recovery Series, CyberSensePropiedades del artículo