PowerProtect Cyber Recovery: Error - "The storage interface name provided for multilink object is not valid"

Resumen: Error when adding an interface to Multilink, stating that the object is invalid.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

Customer is getting this error when trying to configure multi link. 
 
ERROR: Failed to modify application:<CyberSense Server hostname> 
The storage interface name vethx.xxx provided for multilink object with storage ID xxxxx is not valid.



Causa

Issue is due to a limitation with the number of interfaces on the vault Data Domain being more than 20.

Resolución

DD ../network/interfaces REST API only returns 20 interfaces by default, this has been extended to 100 in CR Release 19.13.0.3.

Release Notes/Installation guide for multilink configuration prerequisites must be followed to avoid further issues. 

Productos afectados

Cyber Recovery Series, CyberSense