PowerProtect Data Manager: "Schedule deleting Expired Copies"-jobben mislykkes hele tiden
Resumen: "Schedule Deleting Expired Copies"-jobben mislykkes hele tiden etter oppgradering til PowerProtect Data Manager-versjon 19.13 og 19.14.
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
Det observeres at den daglige "Schedule Deleting Expired Copies"-jobben begynner å mislykkes etter oppgradering til PowerProtect Data Manager 19.13 og 19.14. PowerProtect Data Manager Backup fungerer fint.
PowerProtect Data Manager compliance-verification.log har følgende feil:
PowerProtect Data Manager compliance-verification.log har følgende feil:
2023-08-27T16:00:04.560Z INFO [] [compliance-copy-deletion-157] [][][TASK_ID:8fda58c09790da88][TRACE_ID:9e4f867156a13ce2;JOB_ID:b6dc81e903e5cf88][] [c.e.b.d.d.DDBoostAdapter.connect(322)] - Connecting to PowerProtect DD System, hostname = <DD>, username = <SU_username>, instanceDesc: 343789568 2023-08-27T16:00:04.560Z INFO [] [compliance-copy-deletion-157] [][][TASK_ID:8fda58c09790da88][TRACE_ID:9e4f867156a13ce2;JOB_ID:b6dc81e903e5cf88][] [c.e.b.d.d.DDBoostAdapter.connect(331)] - Connecting using storage unit: <Storage_unit> 2023-08-27T16:00:04.644Z ERROR [] [compliance-copy-deletion-153] [][][TASK_ID:abf0ec942070651b][TRACE_ID:9e4f867156a13ce2;JOB_ID:8ec6f709298d6f70][] [c.e.b.d.c.u.DDCommonUtils.localConnectForDataTarget(236)] - localConnect failed for dataTargetId: c7d94ddd-9911-4053-bb0d-128f4dc6a166 com.emc.brs.datadomain.ddboost.DdboostException: Code: 5075, Message: connect operation failed with code: 5075. errstr=the user has insufficient access rights, errorinfo=[ 1] [140465436579584] Sun Aug 27 16:00:04 2023 ddp_connect_with_config() failed, Hostname: <DD>, Err: 5075-DDBOOST Error 1 for lookup /data/col1/ on <DD> (nfs: Operation not permitted)Data Domain ddfs.info har meldingene nedenfor:
08/28 00:00:04.609645 [7fbe94348530] ddboost: <ecbc62e03c6d-48288>, cipher_info: 0, cipher_strength: 1, auth_mode: 0 08/28 00:00:04.610210 [7fbe8e5bf2a0] ddboost: <ecbc62e03c6d-48286>, cipher_info: 0, cipher_strength: 1, auth_mode: 0 08/28 00:00:04.612674 [7fbe94345ce0] ddboost: <ecbc62e03c6d-48302>, cipher_info: 0, cipher_strength: 1, auth_mode: 0 08/28 00:00:04.615429 [7fb79729e150] ddboost: <ecbc62e03c6d-48270>, cipher_info: 0, cipher_strength: 1, auth_mode: 0 08/28 00:00:04.618361 [7fbe94347600] WARNING: Client ecbc62e03c6d did not match access list entries
Causa
PowerProtect Data Manager 19.13 og 19.14 bruker samsvarsbeholder for sletting av kopier. Sletting av PowerProtect Data Manager Copy mislykkes hvis Data Domain har begrenset klientliste for ddboost, og den tillater ikke samsvarsbeholder-ID for PowerProtect Data Manager som ddboost-klient.
Resolución
Kjør Data Domain-kommandoen nedenfor som en midlertidig løsning:
ddboost clients add *
MERK: I PowerProtect Data Manager 19.15 bruker Compliance Docker cc.PPDM_hostname<> i stedet for beholder-ID for å koble til Data Domain.