Connectrix B-Series: Device Logging In as a Loopback
요약: This article explains why a Connectrix B-Series switch port may detect an attached HBA or storage device as a loopback port and how to troubleshoot the condition.
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
An HBA or storage device automatically configures as a loopback port on a Connectrix B-Series switch.
원인
This could be caused by the controller configuration on the HBA or storage device.
해결
Check whether the end device is configured for Fibre Channel Arbitrated Loop (FC-AL). Also check the integrity of the SFP and cable. Then reset the port as follows:
portcfgpersistentdisableportcfgdefaultportcfgpersistentenable
If the status of the port is still loopback after performing the above, move the cable to a free port. If the issue follows the cable, it is likely an issue with the connected device. Further troubleshooting must be performed at that end.