PPVE- PPVE alerts in kernel logs
요약: Duplicate LUNs presented to server causing PPVE error messages
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
OS: VMware ESXi 6.0.0 build-4192238
PP version:6.1.0.00.00-b56
Product: Symmetrix Remote Data Facility (SRDF),VMAX3 Series, SRDF metro
Error messages seen on vCenter Alerts:
Alarm 'Host error' on vmw13.gtas.cz triggered by event 38075366 'Issue detected on vmw13.gtas.cz in GECO: PowerPath:Status:Already exists. Failed to registerdevice. User should
unclaim paths. (2017-01-11T16:29:13.994Z cpu2:33106)' info "
vmkernel logs report the following error messages:
2017-01-12T12:49:14.094Z cpu13:33102)ScsiUid: 403: Existing device naa.60000970000296801138533030303639 already has uid naa.60000970000296801138533030303639
2017-01-12T12:49:14.094Z cpu13:33102)ScsiDevice: 3719: Failing registration of device: failed to add primary uid naa.60000970000296801138533030303639: Already exists
2017-01-12T12:49:14.094Z cpu13:33102)WARNING: Unnamed device 0x43036da21780 state 0x00000100, stateb4apd 0x00000000, flags 0x00000090
2017-01-12T12:49:14.094Z cpu13:33102)WARNING: Unnamed device 0x43036da21780 state 0x00000100, stateb4apd 0x00000000, flags 0x00000090
2017-01-12T12:49:14.094Z cpu13:33102)WARNING: Unnamed device 0x43036da21780 state 0x00000100, stateb4apd 0x00000000, flags 0x00000090
2017-01-12T12:49:14.094Z cpu13:33102)ScsiEvents: 545: Event Subsystem: Device Events, Destroyed!
2017-01-12T12:49:14.094Z cpu13:33102)ALERT: PowerPath:Status:Already exists. Failed to registerdevice. User should unclaim path
원인
VMAX Microcode bug. The VMAX is sending the incorrect inquiry information so PowerPath sees these as different devices.
해결
Symm H/W to apply Fix 93451 Symm on the box .
Then un-present the duplicate LUNs, HBA rescan, re-present the LUNs, and rescan HBA.
Then un-present the duplicate LUNs, HBA rescan, re-present the LUNs, and rescan HBA.
추가 정보
This is NOT a Powerpath issue
There has been similar issues reported when NMP is being used instead of Powerpath.
In all host environments, it is best practice to not provision the secondary R2 devices to the host before activating SRDF/Metro.
This allows the operating system and multi-pathing software to cleanly detect new paths to the R2 devices when SRDF/Metro reaches Active mode.
There has been similar issues reported when NMP is being used instead of Powerpath.
In all host environments, it is best practice to not provision the secondary R2 devices to the host before activating SRDF/Metro.
This allows the operating system and multi-pathing software to cleanly detect new paths to the R2 devices when SRDF/Metro reaches Active mode.
해당 제품
PowerPath/VE제품
PowerPath, PowerPath/VE, PowerPath/VE for VMware, VMware ESXi문서 속성
문서 번호: 000059388
문서 유형: Solution
마지막 수정 시간: 18 4월 2026
버전: 5
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스