VPLEX: Distributed Device Experiencing Performance Issues

요약: A VPLEX distributed device is experiencing performance issues due to high write latency.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

Hosts are experiencing high write latency on VPLEX distributed devices.

 

원인

For distributed devices, VPLEX confirms that any write I/O is committed to back-end storage on both sites before returning acknowledgement to the host.

If the inter-cluster FC/IP WAN network is experiencing congestion, the round-trip time of I/O packets increases. This increase causes the performance issue.

On the other hand, VPLEX always serves read I/Os from the global cache if the data is available, or from the local back-end array.

VPLEX best practice indicates that the RTT between VPLEX clusters should not exceed 5 ms for optimal performance. For a campus-wide network, the RTT should not exceed 1 ms.

 

해결

  1. Check the firmware logs for com/21 and com/24 events that indicate network congestion.

    Example:

    128.221.253.36/cpu0/log:5988:W/"00601661de2210138-2":141384:<4>2017/04/12 09:16:16.10: com/21 COM IO took 1.047 sec to complete (limit 900.000 msec).  Type message, uuid 0x4xxxxxx, transport scsi, msg_len 72
    128.221.252.38/cpu0/log:5988:W/"0060165322f014450-2":2170302:<3>2016/10/22 23:29:35.92: com/24 86 long-latency IOs in past hour (Msg: 86) Printed up to 100.
  2. Confirm that all WAN com ports are up and that the SFP power is greater than 200 uW. If not, follow the KB article: VPLEX: 0x8a45901c, IP Port detects no receive power or 0x8a453013, IP network link down (Dell Support login may be required)

  3. If the VPLEX is an FC metro configuration and the WAN FC switches are Dell-supported, follow the KB article: Connectrix Switches: How to collect Switch Logs (Primary) (Dell Support login may be required). Collect the switch logs and engage Dell support.

  4. If the VPlex is IP metro configuration, validate the IP network health to determine what is causing the congestion.

 

해당 제품