VNX: How to attach same CIFS interface as NFS to the same VDM

요약: It is only possible to attach the same CIFS Interface as NFS to the same VDM through CLI Commands.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

Connect to the Control Station SSH.

In order to view the interfaces attached as CIFS or NFS , apply the below command:
$nas_server -i -v <VDM_Name>

Example:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs


The above example shows Interface Name "nl0123nas0002_390" is attached as CIFS only, and Interface Name "Prodspace" is attached as CIFS and NFS.

To attach the same CIFS interface as NFS apply the below command:
$nas_server - vdm <VDM_Name> -attach <Interface_Name>

Example:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs