PowerScale: iDRAC experiences connectivity problems

요약: The following event is displayed on the cluster. The Integrated Dell Remote Access Controller (iDRAC) located in chassis {chassis} is experiencing connectivity problems. This controller monitors hardware components such as batteries and power supplies. To ensure that these hardware components continue to be monitored, contact Dell support. This may be caused by an unresponsive PowerTools Agent process. PTAgent is the process that facilitates communication between the iDRAC and OneFS' hardware monitoring subsystem. ...

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

To identify the node on which the Alert was seen 

# isi event events list | grep -i IDRAC 

26.954089  02/01 00:21 C    5    1336539        The Integrated Dell Remote Access Controller (iDRAC) located in chassis HCBPFV3 is experiencing connectivity problems. This controller monitors hardware components such as batteries and power supplies. To ensure these 

To check the status of IDRAC connection on a particular node.
Open an SSH connection to the specific Node in the cluster and log in using the "root" account.
Run the following command,
 

# isi_hwmon -a | grep -i iDRAC 

Test :  --- IDRACServices Diagnostics ---
Test :  iDRAC USB NIC State
Test :      idraccache: OK
Test :      idracConnection: OK
Test :  --- IDRACServices Diagnostics ---


To check the status of IDRAC connection on all the Nodes

# isi_for_array -s isi_hwmon -a | grep -i iDRAC 


If the idracConnection status is not OK or if numerous alerts indicate that IDRAC is experiencing connectivity problems, contact PowerScale Support.

 

iDRAC Component Errors — "No Valid Labels"

If the iDRAC hardware inventory or sensor list displays components with missing, blank, or "no valid labels" entries, this typically indicates that the PTAgent process is unable to relay component label information between OneFS and the iDRAC.

Common causes:

  • Unresponsive PTAgent process (see the Additional Information section below for PTAgent restart guidance)
  • The isi_security_checker cron job overloading the iDRAC (see PowerScale iDRAC is Experiencing Connectivity Issues — applicable to F200, F600, F900, P100, and B100 series nodes only)
  • iDRAC firmware issues

Diagnostic steps:

  1. Check iDRAC connection status on the affected node: isi_hwmon -a | grep -i iDRAC
  2. Check across all nodes: isi_for_array -s isi_hwmon -a | grep -i iDRAC
  3. If the idracConnection status shows anything other than OK, contact Dell PowerScale Support. Do not modify iDRAC or BIOS settings without Dell Support approval (see KB Changing iDRAC settings on a PowerScale node).

Dell.com Validation Source(s):

추가 정보

Support can see the following article to confirm if PTAgent must be restarted to fix the issue.
PowerScale: Isilon: Gen6.5 node in Read-Only mode with iDRAC and NVDIMM alerts (Dell portal login required)

해당 제품

Isilon, PowerScale
문서 속성
문서 번호: 000222465
문서 유형: How To
마지막 수정 시간: 28 7월 2026
버전:  3
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.