PowerFlex 4.X: Configuring SNMP on the resources for webhook

요약: For the SNMP alerts to be forwarded to a site like BigPanda, the load balancer IP address of the management virtual machine is configured on each of the resources individually.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

Configuring SNMP on the resources for webhook

For the SNMP alerts to be forwarded to a site like BigPanda, the load balancer IP address of the management virtual machine is configured on each of the resources individually.

The resources like CloudLink, IDRAC, and the switches should be discovered and managed in PowerFlex Manager.


Note: For a webhook destination, SNMPv3 is supported for iDRAC.
 

SNMPv2c is supported for all resource types like CloudLink, iDRAC, and switches.

Identify the SNMP load balancer IP address.

Use this procedure to identify the SNMP load balancer IP address on the management virtual machines.

Steps

To identify the load balancer IP address on the management virtual machine, type: 

#kubectl get svc -A |grep -i LoadBalancer

Example output:

example output 1 example output 2 

If an OOB SNMP load balancer IP address is not listed, see article PowerFlex 4.0.1 SNMP or syslog alerts not working due to missing OOB load balancer IP